Herunterladen Inhalt Inhalt Diese Seite drucken

Stroke/End Position Setting; E 170; E 212 - GEZE E 170 /230 V AC Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

E 170 / E 212 R1 / E 212 R / E 212
7

Stroke/end position setting

7. 1
E 170
See mounting instructions ID. 128689 (40422-9-0950).
7.2
E 212
1
LED (green)
2
Setting screw stroke
The stroke is set to 52 mm in the factory.
Set and check the stroke according to fitting stroke
X
X
Setting value = Fitting stroke – 2 mm
Example OL 90: Setting stroke 54 mm = Setting value drive 52 mm
Check the setting by means of a test run and make sure of correct
X
X
switch-off. The LED on the drive lights up green while the motor is run-
ning. When the drive reaches the end switch and switches off properly,
the LED goes out. The LED flashes if the end switch setting is not correct.
212 R / 230 V
With drive 212 R the LED only flashes if the actuation signal is permanent-
ly queued i.e. the key is pressed.