– Use this appliance only for the purpose for which it was designed as specified in this
user's manual. Never use the appliance for any other purpose.
– The producer does not undertake any responsibility for damage caused by improper use
of the appliance (e.g. injury, fire, etc.) and its guarantee does not cover the appliance in
the case of failure to comply with the safety warning above.
II. DESCRIPTION OF THE APPLIANCE (Fig. 1)
A – humidifier (base)
A1 – knob for controlling the amount of vapour / ON/OFF
A2 – light signalling
A3 – vessel for aromatic additives with pad (ETA062800100) + filter (ETA062800060)
A4 – ultrasound converter
B – water tank (ETA062800070)
B1 – lid with a baffle
B2 – handle
III. PREPARATION FOR USE
Remove all packaging, take the humidifier out. Remove all adhesion foils, stickers or paper
from the humidifier.
The ultrasound humidifier creates microscopic drops of water with the diameter of about 1
– 5 μm using high-frequency oscillator. The ventilation system then blows them out in the
form of vapour (fog) into the room where they evaporate and thus increase air humidity.
INSTRUCTIONS FOR USE
1. Place the humidifier on a suitable flat surface.
2. Remove the tank B from the humidifier A in accordance with Pic. 1.
3. After unscrewing B3 valve fill the tank B with water (at least 300 ml, ideally 1 – 3 l). You
can place a suitable aromatic additive in the vessel A3.
4. Place the tank B on the humidifier A in a reverse way.
5. Connect the plug to the power supply.
6. Turn the humidifier on by turning the knob A1 clockwise and set the required intensity of
water vapour (the light indicator A2 is lit).
7. You can turn the humidifier off any time by turning the knob A1 into the ON/OFF position.
– The humidifier is designed for creating optimal air humidity in the room and it also
limits the occurrence of static electricity.
– As soon as the water level drops below the operating minimum, the humidifier
automatically stops the production of vapour.
– Only add a few drops of liquid aromatic additives to the vessel A5 (on the foam filter).
– The maximum volume of the tank provides operation for about 13 hours.
– If you do not use the humidifier for more than one day, pour out the unused water
from the tank and the internal parts of the humidifier.
IV. MAINTENANCE
Clean the surface of the appliance with a damp cloth. Rinse the vessel for aromatic additives
with warm water. Rinse the tank in warm soapy water. You may also use disinfectants but always
follow the instructions provided on the packaging. Clean the ultrasound converter with a cloth
(sponge) and warm soapy water. If you use the humidifier frequently, we recommend cleaning
the tank and the ultrasound converter at least once a week.
B3 – cap with a valve
Note
Notes
15