Herunterladen Inhalt Inhalt Diese Seite drucken

How To Check Nanoe™ X Connection (Existing Unit) - Panasonic nanoe X CZ-CNEXU1 Installationsanleitung

Vorschau ausblenden Andere Handbücher für nanoe X CZ-CNEXU1:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 26
Installation
How to Check nanoe™ X Connection (Existing unit)
 How to check the connection of nanoe™ X installed at existing indoor unit.
(Remote controller which is adaptable to nanoe™ X function is required.)
1. Switch Off the earth leakage circuit breaker.
2. Install the nanoe™ X kit in the accordance with the following method of the nanoe™ X kit
installation and wiring processing.
3. Switch On the earth leakage circuit breaker.
4. Wait until the remote control display returns to ordinary
mode.
5. Operate the unit in FAN mode.
6. While operating in FAN mode (more than 5 minutes have
elapsed), press
4 or more seconds to make "Maintenance func" display.
7. With pressing
(Unless the nanoe™ X connection is made,
check each Unit no. whether connected or not. If "Normal" appears, it is available.
8. If it is unable to enter the "nanoe" menu or "Unsupported", "Faulty connection" or "Not
connected" is displayed, switch Off the earth leakage circuit breaker. Try to unplug the
connector of nanoe™ X kit from the PCB. Then plug it in again.
Once again check the Steps 1 to 6. However, if the same above symptom occurs, there is
something wrong with the kit. Contact the dealership you purchased.
8
+
+
simultaneously for
/
, select "13. nanoe" and press
. "nanoe" menu appears.
will not be displayed.) It is possible to

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis