Adjustment Procedures

GB
Tape Deck
Measuring instruments/Test equipment:
AF voltmeter, frequency counter, Cr test cassette (3150Hz / 10kHz) e.g. 448A
Adjustment
1. Azimuth
Access to the azimuth adjustment screw of the audio head
is possible through small cutout on the front panel.
Play back the 10kHz sound section on the Cr test cassette.
AF voltmeter to Loudspeaker outputs.
2. Speed
Load Cr test cassette and play back the 3150Hz sound
section.
Frequency counter to Loudspeaker outputs.
2 - 2
Preparation
Adjustment Procedure
Set the left and right channel with the azimuth screw for
same maximum.
Azimuth
U M S 15
R E M O T E C O N T R O L L E D H I F I S T E R E O M I C R O S Y S T E M
F U L L A U T O S T O P
R E C .
P L AY
R E W.
With motorpoti set the frequency to 3150Hz
Motorpoti
UMS 15
F. F W D .
S T O P / E J E C T
PA U S E
±
50Hz.