Copy function:
– Press and hold the button Hold/Copy (11). The current
measuring value (e) is copied and the indicator H is shown
continuously on the display.
– Briefly press the button Hold/Copy (11). The stored meas-
uring value (e) is shown on the display and the indicator H
flashes.
– Place the measuring tool in the location to which the meas-
ured value is to be transferred. When doing so, the alignment
of the measuring tool is irrelevant. The alignment aids (a)
show which direction the measuring tool has to be moved in
to reach the grade you want to copy. When the stored grade
is reached, an audio signal sounds and the alignment aids (a)
go out.
– Briefly press the button Hold/Copy (11) again to return to
normal measurement. The indicator H is shown continuously
on the display.
– Press and hold the button Hold/Copy (11) to save a new
value.
– To delete a hold value, briefly press the on/off button (9).
Accuracy Check and Calibration of the Measuring
Tool
Checking the Measuring Accuracy (see figure B)
Check the accuracy of the measuring tool prior to critical meas-
urements, after intense variations in temperature as well as
after heavy impact.
Before measuring grades < 45°, the accuracy check should take
place on a level and roughly horizontal surface; before measur-
ing grades > 45°, on a level and roughly vertical surface.
Switch on the measuring tool and place it on the horizontal/ver-
tical surface.
Select the measuring unit ° (see "Changing the Measuring Unit
(see figure A)", page 14).
Wait for ten seconds and note down the measured value.
Rotate the measuring tool by 180° around its vertical axis. Wait
again for ten seconds and note down the second measured
value.
Calibrate the measuring tool only when the difference
u
between both measured values is greater than 0.1°.
Calibrate the measuring tool in the position (vertical or hori-
zontal), in which the difference of the measured values has been
determined.
Calibration for Horizontal Surfaces (see figure C)
The surface onto which you place the measuring tool must not
deviate from the horizontal surface by more than 5°. If the devi-
ation is greater, the calibration process is discontinued with the
indicator ‑‑‑.
Switch on the measuring tool and position it on the hori-
zontal surface so that the spirit level for horizontal align-
ment (1) faces upwards and the display (5) faces you.
Wait for ten seconds.
Then press the calibration button Cal (10) for approx.
two seconds until CAL1 appears briefly on the display.
Then the measured value will flash on the display.
Turn the measuring tool 180° around the vertical axis so
that the spirit level still faces upwards but the display (5)
is facing away from you. Wait for ten seconds.
Then press the calibration button Cal (10) again. CAL2
will be shown briefly on the display. Then the measured
value (no longer flashing) will appear on the display. The
measuring tool has now been recalibrated for this sup-
porting surface.
Afterwards you must calibrate the measuring tool for the
opposite surface. Rotate the measuring tool around the
horizontal axis so that the spirit level for horizontal align-
ment (1) faces downwards and the display (5) faces
you. Place the measuring tool on the horizontal surface.
Wait for ten seconds.
Then press the calibration button Cal (10) for approx.
two seconds until CAL1 appears briefly on the display.
Then the measured value will flash on the display.
Turn the measuring tool 180° around the vertical axis so
that the spirit level still faces downwards but the dis-
play (5) is facing away from you. Wait for ten seconds.
Then press the calibration button Cal (10) again. CAL2
will be shown briefly on the display. Then the measured
value (no longer flashing) will appear on the display. The
measuring tool has now been recalibrated for both hori-
zontal supporting surfaces.
Bosch Power Tools
English | 15