Errors
The SYSTEM indicator notifies you of various errors that can occur on the unit. Refer to the
following section to resolve the errors. Always check whether an error notification also
appears on IP Live System Manager.
SYSTEM indicator
Rapid blinking
(orange, 0.5-sec.
interval)
Blinks 3 times
(orange)
Blinking (green)
Blinks 4 times
(orange)
Blinking (orange, 1-
sec. interval)
Blinks 2 times
(orange)
Description
Fan error
Network error
Network
synchronization in
progress
Other error
Internal temperature
error
Low optical module
power supply
Solution
A fan error has occurred.
A network error has occurred. Check the
network connection.
Network synchronization is in progress. If the
problem does not resolve itself after a
moment, contact your local Sony
representative.
A system error has occurred. Contact your
local Sony representative.
An internal temperature error has occurred.
Check the operating environment.
The power supplied to the optical modules
installed at NMI LAN connectors 1 and 2 is
low.
Clean the optical connectors and the contacts
on the optical fiber cable, or replace the
optical modules. For details on cleaning or
replacing optical modules, contact your local
Sony representative.