Herunterladen Inhalt Inhalt Diese Seite drucken

Lens Mounting - Bosch Dinion XF LTC 0610 Serie Installationshandbuch

15-bit digitale farbkamera
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 59
Dinion
XF
| Installation Manual
Alarm connector
Pin
1
2
3
4
Max. wire diameter AWG 22-28 for both stranded and solid
Default relay position n.o. (normally open), no alarm
Alarm output relay switching capability: Max voltage 30VAC or
+40VDC. Max 0.5 A continuous, 10VA.
Alarm in: TTL logic, +5V nominal, +40VDC max, DC coupled with
22kΩ pull-up to +3.3V
Alarm in: configurable as active low or active high
Max. 42V allowed between camera ground and each of the relay pins.

Lens mounting

The camera accepts both C and CS-mount lenses. DC-iris lenses are
recommended for the best picture performance. The camera automatically
detects the type of lens used and optimizes performance accordingly.
A spare male lens connector is provided.
Caution
To avoid damaging the CCD sensor when using a C-mount lens,
turn the red back focus ring counterclockwise until it stops (see
back focus adjustment) before mounting the lens.
Lenses weighing more than 0.5 kg (1.1lbs) must be separately
supported.
Bosch Security Systems | 2003-10 | V0.5
Alarm socket
Ground
Alarm in
Relay out contact 1
Relay out contact 2
EN | 10
Alarm
Pin 1
Pin 4