Herunterladen Inhalt Inhalt Diese Seite drucken

Velleman DCM100 Bedienungsanleitung Seite 9

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 46
9.2 AC CURRENT
range
2 A
20 A
200 A
500 A
Average sensing, calibrated to rms of sine wave
Frequency response: 50 Hz-60 Hz
Overload protection: 600 A rms within 60 sec
9.3 RESISTANCE
range
200 Ω
2 kΩ
20 kΩ
200 kΩ
2 MΩ
20 MΩ
Overload protection: 250 V DC or AC rms
9.4 DIODE + AUDIBLE CONTINUITY
range
Overload protection: 250 V DC or AC rms
V. 03 – 05/07/2019
Do not measure circuits that may contain voltages
resolution
0.001 A
0.01 A
0.1 A
1 A
Do not conduct resistance measurements on live
resolution
0.1 Ω
1 Ω
10 Ω
0.1 kΩ
1 kΩ
0.01 MΩ
Do not conduct diode and continuity measurements on
built-in buzzer sounds if resistance < 70 Ω ± 30 Ω
testing current ± 0.6 mA
open-circuit voltage ± 1.5 V
DCM100
> 600 V AC or DC
accuracy
± (4.0 % + 10)
± (2.5 % + 5)
circuits
accuracy
± (1.0 % + 2)
± (1.5 % + 2)
± (2.0 % + 3)
live circuits
function
9
©Velleman nv

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis