ENGLISH
(Original instructions)
TECHNICAL DATA
Model number
Type of tool .................................................................... 16 Gauge Lightweight finish nailer
Dimension .................................................................... 292 x 74 x 272
Weight of tool ................................................................ 1.6 Kg
Weight according to EPTA-Procedure 01/2003
Compressed air
Maximum permissble operating pressure ................. 8 bar
Recommended operating pressure ........................... 5 – 8 bar
Air consumption per driving operation........................ Technical data 1.249 sl/cycle 0.04 scf/cycle
Recommended lubrications
Fastener specifications ................................................. 1.6 x 1.4 length 20 – 64 mm (16 gauge)
Acessories..................................................................... 3 and 4 mm wrenches
Aplications & suitability.................................................. Paneling, door/window casings, and furniture frames
Actuating system (safety yoke installed).................... Contact/Single sequential actuation
Trigger device ................................................................ Finger pressure activation
Filling the magazine
1.
Pull back the spring loaded pusher until it latches into position.
2.
Load up to 2 strips or 100 nails into the top of the magazine.
3.
Press the latching mechanism to allow pusher return to its original position, remembering to keep fingers clear.
1. SPECIAL REFERENCES
1.1 REGULATIONS
The following standard is applicable to fastener driving
tools:
EN 792-13 »Hand-held non-electric power tools – safety
requirements – Part 13: Fastener driving tools«.
This standard requires that
• only those fasteners which are specified in the operat-
ing instructions (see technical data) shall be used in
fastener driving tools. The fastener driving tool and the
fasteners specified in the operating instructions are to
be considered as one single safety system;
• quick-action couplings shall be used for connection to
the compressed air system and the non-sealable nipple
must be fitted to the tool in such a way that no com-
pressed air remains in the tool after disconnection;
• oxygen or combustible gases shall not be used as an
energy source for compressed air operated fastener
driving tools due to the danger of fire or explosion;
• fastener driving tools shall only be connected to an air-
supply where the maximum permissible operating pres-
sure of the tool cannot be exceeded by more than 10%;
in the case of higher pressures, a pressure reducing
valve which includes a downstream safety valve shall
be built into the compressed air supply;
• only spare parts specified by the manufacturer or his
authorised representative shall be used in the repair of
fastener driving tools; repairs shall be carried out only
by the manufacturers authorised agents or by other
specialists, having due regard to the information given
in the operating instructions.
Note: Specialists are those who, as a result of profes-
sional training or experience, have sufficient expertise in
the field of fastener driving tools and suffi cient familiarity
with relevant industrial protection provisions to be able to
assess the safe condition of fastener driving tools.
2
AF600
• stands for mounting the fastener driving tools to a sup-
port, for example to a work table, shall be designed and
constructed by the stand manufacturer in such a way
that the fastener driving tools can be safely fixed for the
intended use, thus for example avoiding damage, dis-
tortion, displacement.
1.2 NOISE EMISSION
The characteristic noise values for the fastener driving
tool
have
been
EN 12 549.
These values are tool-related characteristic values and
do not represent the noise development at the point of
use. Noise development at the point of use will for exam-
ple depend on the working environment, the workpiece,
the workpiece support and the number of driving opera-
tions, etc.
Depending on the conditions at the workplace and the
form of the workpiece, individual noise attenuation mea-
sures may need to be carried out, such as placing work-
pieces
on
sound-damping
workpiece vibration by means of clamping or covering,
adjusting to the minimum air pressure required for the
operation involved, etc.
In special cases it is necessary to wear ear protection
equipment.
1.3 INFORMATION ON MECHANICAL IMPACT
(VIBRATION)
The characteristic vibration values for the fastener driving
tool
have
been
ISO 8662-11.
This value is a tool-related characteristic value and does
not represent the influence to the hand-arm-system
when using the tool. An influence to the hand-arm-sys-
tem when using the tool will for example depend on the
gripping force, the contact pressure force, the working
direction, the adjustment of mains supply, the workpiece,
the workpiece support.
determined
in
accordance
supports,
determined
in
accordance
with
preventing
with