Web server settings
• The following settings are made depending on the given
application.
• Edit settings: Click the red pencil symbol .
• Settings marked with an asterisk (*): Applies to OZS164.23 only.
13. Select "Home" from primary navigation:
Home > 0.5 OZW672...
Home > 0.5 OZS164...
14. ...> Time of day/date: Time of day/date
15. ...> Settings > Web server: Language
16. ...> Settings > Time of day/date:
Summer time start, Winter time start
17. ...> Settings > Communication > :
Device number, Clock time source
18. ...> Settings > Communication > Ethernet:
Automatically via DHCP client. After connecting to the LAN,
the IP address can be read via USB.
As an option: Manually (see below and
− IP address: Web server IP address.
− Subnet mask: Generally the same as for the router.
− Default gateway: Router IP address.
− Preferred DNS server: Router IP address.
− Alternate DNS server: Generally empty.
− UPnP localization: Select USB or Ethernet
19. ...> Settings > Communication > E-mail:
Address mail server, Port number mail server, E-mail address
sender, Authentification mail server, User name, Password,
Signature line 1...10
20. (*) ...> Settings > Communication > Modem: PIN SIM card,
Transmission protocol
21. (*) ...> Settings > SMS operation: Permitted phone number 1...5,
Password
22. ...> Settings > Message receiver >
Message receiver 1...4: Message receiver 1...4, Fault priority,
Receiver type, E-mail address, Phone number receiver (*),
Message repetition (*)
23. ...> Settings > System report:
Signal time, Message cycle, Priority, Next report
24. ...> Settings > Inputs > Fault input 1...2:
Normal position, Text for: Logic 0 / 1
25. ...> Settings > Faults > Local > Web server: Message triggering
26. ...> Settings > Faults > Local > Fault input 1...2: Fault input 1...2,
Fault status message delay, Fault priority, Message triggering,
Text for: No fault, Text for: Fault
27. ...> Settings > Faults > System: Message triggering
28. ...> Settings > Texts: Name, Name bus device (OZS164... only)
Router settings
• The settings (example, see
server outside the PC network (e.g. via the Internet).
29. NAT/PAT for the Web server must be enabled on the router.
30. Moreover, the DynDNS settings are required on the router, when
the router is operated on a public IP address using a dynamic IP
address.
en 8 / 8
06.06.2012
10
)
10
) are required to access the Web
G5711xx
74 319 0703 0 c
Final tasks
31. Unplug USB cable.
32. Switch off message suppression.
− Remove the cover.
− Switch (8) must be set to OFF
− Remount the cover.
33. Press button (6)
long (>6 s)
• The Web server sends a system report to the defined message
receivers.
• Communications errors are displayed on the red fault LED
(flashing).
Final on-site check
34. ON LED
must be green or orange.
35. Fault LED
must be off.

Display and operating elements

11
See Figure
LED displays
1 ON
(red/green/orange)
Dark
No power.
Steady red
Web server starting (operating system).
Flashing red
Web server starting (application).
Steady green/orange Web server operational, "Energy indicator =
Green leaf or Orange leaf".
2 LPB/BSB A
(green)
Dark
No bus power.
Lit
LPB/BSB operational.
Flashing
Communication on LPB/BSB.
3 (LED) B
Dark
No function.
4 Fault
(red)
Displays faults from the Web server or the connected bus device:
Dark
No fault.
Lit
Acknowledged fault.
Flashing
Unacknowledged fault
5 (LED)
Dark
No function.
Operating buttons
The following applies when pressing the buttons:
Short:
<2 seconds.
Long:
<6 seconds.
6 Remote
Short
No function.
Long
Sends system report to the configured fault e-mail
receivers; see as well "Button combination".
7 Service button
Short
No function.
Long
See "Button combination".
Button combination
and
Short
No function.
Long
Reestablishes default state.
Note on "default state":
• All configuration data and settings are reset.
• The device list, plant diagrams, and unsent messages are deleted.
• History data is not deleted.
.
11
(4)