Attention! The fitting must be installed, flushed and tested
after the valid norms!
Adjustment
Correction is necessary if the temperature measured at the
take off point differs from the temperature set on the scale.
To adjust temperature proceed as follows:
Turn the setting knob until water at a temperature of 38°
C comes out of the outlet. Loosen screw of setting knob.
Remove setting knob and turn to the 38° C position.
Attach setting knob again and tighten the screw (please
see page 67).

Temperature limitation

The temperature is limited by the safety check to 38°
C (100° F). If a higher temperature is required, it is
possible to override the safety stop by depressing the
safety button.
Safety Function
The desired maximum temperature for example max. 42°
C can be pre-set thanks to the safety function (please see
page 66).
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow by 0,3 MPa

Maintenance

There is no special maintenance for thermostats. The non
return valves (6) must be checked regularly according to
DIN EN 1717 in accordance with national or regional
regulations (at least once a year). At this time, please
also check the filter (.1) situated on the MTC-thermo-
element (). After assembling the MTC-thermo-element,
it is necessary to check the water temperature at the take
off point as described under the headline „adjustment".
Before the adjustment, please check, if the warm water
supply is activated and the maximum temperature of the
warm water is available at the take off point.
1
English
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80° C
65° C
approx. 26 l/min
To guarantee the smooth running of the thermostat, it is
necessary from time to time to turn the thermostat from
total hot to total cold.
Spare parts (see page 3)
1
handle for thermostat
2
face plate
3
sleeve
4
thermostat cartridge
5
noise reduction
6
non return valve
7
shut off unit with selector
8
sub plate
9
fixing screw
10
sleeve
11
handle
12
extension set 25 mm
13
extension set 22 mm
14
adapter for handle
15
adapter for handle
sealing set
16
17
screw
18
hollow set screw
19
screw cover
11791000
95174000
96439XXX
94282000
94073000
94074000
96509000
96447000
96454000
96446XXX
95176000
13595000
98860000
96435000
95177000
95037000
96525000
97663000
94181000

Werbung