IMPORTANT:
e.g.:
Application:
Functioning:
A
Rectifier
Art. No.: 161675
Art. No.: 161677
Art. No.: 161676
Art. No.: 161674
Art. No.: 16168 ..
B
Connection diagram Various examples for FALLER Car System components.
Button
T ...
Switch
S ...
Technical data:
161668 rectifier
It is also possible to connect more components than specified above,
if the sum of the
»required power«
of the
20 stop points, of which 10 pcs. are »ACTIVE«
20 branches, electrical, of which 8 pcs. are »ACTIVE«
20 2 LED bar spotlights
There is a remaining amount of 516 mA for components to be activated by »buttons«.
These are:
3 pcs. of stop points
3 pcs. of branches
2 pcs. - one stop point and
Manual control of the FALLER Car System
It transforms AC into DC.
The rectifier is connected to a transformer 12 -16 V AC,
e.g. FALLER transformer Art. No. 180641.
Switching of the individual components by:
Stop point
Switch
Branch, electrical
Button (without series resistor) or
Switch (with 47-Ohm series resistor)
Branch
Button
Parking lot
Button
Magnet enable coil
Button
Instantaneous switch
Voltage only as long as button is operated.
Continuous - ON / OFF
Voltage is permanently ON / OFF.
Input voltage
12 - 16 V AC
Current input up to
3000 mA AC (5 - 10 minutes)
Output voltage
at 12 VAC approx. 16.9 V DC
(unloaded)
at 16 VAC approx. 22.6 V DC
Max. continuous current loading 2500 mA DC
»ACTIVE components«
does not exceed
10 x 138 mA =
1380 mA
8 x 138 mA =
1104 mA
SUM
=
2484 mA
40 x 60 mA =
2400 mA
or
or
one
branch
2500 mA.
5