(The details on the type plate apply)
Type
Rated output
Rated current
Fuses
Selectable output
Pressure drop *
with DMB
without DMB
Throughput limit (DMB)
Nominal capacity
Type
Rated operating pressure
Weight
Protection class to EN 60335
Protection level to EN 60529
Test symbols
Building Regulation test
certificate [Germany]
Water connection
Power supply
Bare wire heating system
Cold water inlet temperature
Application area
Throughput "ON"
Table 3
5.2
Application areas
Details as
Resistance
Conductivity
Conductivity
Table 4
noise emissions has been issued for the instantaneous water heater series
DDLE Basis 18 DDLE Basis 18/21/24
kW 18
A 26.0
A 25
no
MPa (bar) / l/min
0.08 (0.8) / 5.2
MPa (bar) / l/min
0.06 (0.6) / 5.2
l/min
8.0
Colour
white
0.4 l
sealed/unvented
1 MPa (10 bar)
3.6 kg
1
IP 25
see type plate
PA-IX xxxx/I applied for
G ½" (male thread)
3/PE ~ 400 V - 50/60 Hz
900 cm (see Table 4)
max. 25 °C
water with low lime-scale levels and those with lime-scale content
3.0 l/min
application ranges for different reference temperatures
standard details
at 15 °C
cm
900
111
mS/m
1110
µS/cm
for contractors
with selectable output
18
21
28.5
30.3
32
32
yes
yes
0.08 (0.8) / 5.2
0.1 (1.0) / 6.0
0.06 (0.6) / 5.2
0.08 (0.8) / 6.0
8.0
8.0
white
white
at 20 °C
at 25 °C
800
735
125
136
1250
1360
For contractors
DDLE Basis 27
24
27
34.6
39
35
40
yes
no
0.13 (1.3) / 6.9
0.16 (1.6) / 7.7
0.10 (1.0) / 6.9
0.12 (1.2) / 7.7
9.0
9.0
orange
orange
AEG
DIN 4109
PA-IX xxxx/I
31