18 | English
Inverter Mode
Problem
Possible Cause
Product does not
On/Off switch button not properly activated
operate
Temperature too high or too low
Load plug is not inserted properly into the product
outlet socket
Overload switch tripped off – socket outlet over-
loaded
Product works but shuts down within 5 min – load
too high
Connected product in use has been damaged
Connected product cable faulty
The product is damaged
Combined Mode
Problem
Possible Cause
Product does not
Faulty mains power cable or plug
operate
Wrong mains power cable
Product power cable not properly plugged
Residual Current Device (RCD) or Miniature Circuit
Breaker (MCB) – tripped off
Supply voltage outside range
Temperature too high or too low
Socket outlet overloaded
Load plug is not inserted properly into the product
outlet socket
Battery charge level too low
The product is damaged
Product charges
Socket outlet overloaded
slowly
If you are unable to resolve the problem using the troubleshooting guide then please contact your dealer in the first instance.
These conditions may change if you are using Class I or Class II tools with the product: please contact an electrician or the dealer
for advice.
1 609 92A 3EZ | (27.10.16)
Corrective Action
Press down the product on/off switch button for
3 s
Product will not operate until temperature is within
limits (refer to specification), let product cool
down or warm up
Insert load plug fully into the product outlet socket
Reduce load from the outlet sockets and reset the
overload switch.
If this activates in rain: dry out the outlet socket and
restart the product.
Reduce load from the output sockets and reset the
overload switch
If two outlet sockets are loaded: connect one prod-
uct after the other in at least 3 minutes interval
Remove damaged product from the output socket
and reset the overload switch
Replace faulty product cable
Replace product
Corrective Action
Replace mains power cable or blown fuse (UK 13 A
adapter)
Use the specified power cable
Insert mains plug fully into the mains input socket
Reset the RCD or MCB
Remove any extension cable used and charge the
product using the wall socket
Check that the supply voltage is within
220 – 240 V
Product will not charge until temperature is within
limits (refer to specification), let product cool
down or warm up
Reduce load from the outlet sockets and reset the
overload switch.
If this activates in rain: dry out the outlet socket and
restart the product.
Insert load plug fully into the product outlet socket
Plug in mains to charge the product.
Replace product
Reduce load from the outlet socket (above 1000 W
load will slow down the charging rate)