OBJ_BUCH-2030-004.book Page 22 Monday, September 14, 2015 11:19 AM
22 | English
Keep the measuring tool away from cardiac pace-
makers. The magnet inside the measuring tool gener-
ates a field that can impair the function of cardiac pace-
makers.
Keep the measuring tool away from magnetic data media and mag-
netically-sensitive equipment. The effect of the magnet can lead to
irreversible data loss.
Product Description and Specifications
Intended Use
The measuring tool is intended to determine and check horizontal and
vertical lines as well as lines at a defined angle. Moreover, the measuring
tool is intended to determine the angles of objects.
The measuring tool is suitable exclusively for operation in enclosed work-
ing sites.
The measuring tool is not intended for commercial use.
Product Features
The numbering of the product features shown refers to the illustration of
the measuring tool on the graphic page.
1 Laser line
2 Mode button
3 Cal calibration button
4 Display
5 On/Off switch
On Automatic levelling on
On Tilt function with angle indicator on
Off Measuring tool off
6 Tripod mount 1/4"
7 Battery lid
8 Latch of battery lid
1 609 92A 13M | (14.9.15)
Bosch Power Tools