10. Troubleshooting guide

Faults
The equipment does not start
The equipment does not pump
The equipment does not cut out
Insufficient pumping rate
The equipment switches off after
briefly running
Cause
-
Power supply not connected
-
Floating switch does trigger
-
Intake sieve clogged
-
Discharge hose kinked
-
Floating switch cannot sink
-
Intake sieve clogged
-
Performance reduced due to
heavily contaminated and
abrasive water impurities
-
Motor circuit-breaker switches
the equipment off due to
excessive water contamination
-
Water temperature too high;
motor circuit-breaker switches
the equipment off
GB
Remedy
-
Check power supply
-
Raise position of floating switch
-
Clean intake sieve with water jet
-
Unkink the hose
-
Place equipment correctly on
shaft bottom
-
Clean intake sieve
-
Clean equipment and replace
wear parts
-
Unplug power plug and clean
equipment and shaft
-
Ensure that maximum
permissible water temperature
(35 °C) is not exceeded