Please mind the following safety notes to avoid
malfunctions, damages or physical injuries:
▪ To prevent accidents please mount the tap column only on a tilt
resistant and firm foundation which is able to take a load such as
stone slabs, concrete base. Use screws and dowel pins which
are adapted for the used foundation.
▪ Do not use the tap column to deliver drink water.
Application
This column is only intended for use with water. Do not use it to deliver
aggressive chemicals, sewage, acidic or flammable liquids as well as
abrasive substances.
Water contaminated by gravel, silt, sand or similar material may
damage the column.
Mounting the Column
1. Please keep in mind that the column must be cut off from the water
mains and drained during the frosty season. Provide suitable valves or
other means.
2. Build or install a suitable foundation and put the column on the
foundation and align the holes at the pump base.
3. Mark the holes and drill 4 holes into the foundation at the marked
positions by using a suited drill. The mounting holes on the column are
intended for a screw diameter of 8 mm.
4. Insert dowel pins into the drilled holes in
accordance to the screw size (screws not
included). You can connect the column on a water
pipe G ½".
5. Collimate the holes of the flange connection and
bolt down the column with suitable screws.
Safety Notes and Using