BOS R254K-UUI-RH10-S4
Photoelectric Sensors
7
System Functions (continued)
7.8
Profile Characteristic
7.8.1
Description
Profile Characteristic is a readable parameter that provides
information about which IO-Link profiles are supported. It
is used mainly to allow profile function modules of the
control unit to detect which profile or functions on the
device are available.
This parameter is defined in the IO-Link specification.
7.8.2
ISDU
Name
Index
Profile Characteristic
0x000D (13)
Tab. 7-28: Profile Characteristic – ISDU
The parameter can be read via subindex 0 and consists of
multiple profile indices and function classes.
If a profile ID is specified, this means that all included
function classes are supported. If only sub-functions are
specified, these are output explicitly as an individual
function class (16-bit values in each case).
The following function classes are supported:
Variant
Function Class ID
1
0x0007
0x0008
0x0009
0x0030
0x0031
0x4000
2...5
0x0001
0x0030
0x0031
0x4000
0x8001
0x8004
0x8007
0x8008
0x8009
0x800C
Tab. 7-29: Profile Characteristic – supported function classes
www.balluff.com
All individual functions are described in this guide.
For more exact descriptions of the profiles, refer to the
corresponding profile specifications (see www.io-link.com).
Subindex
Access
Variant
0
R
2...5
Name / Description
SSP 2.4 = Adjustable Switching Sensor, single value teach, disable function
SSP 2.5 = Adjustable Switching Sensor, two value teach, disable function
SSP 2.6 = Adjustable Switching Sensor, dynamic teach, disable function
BLOB
FW-Update
Identification and Diagnosis
Generic Profiled Sensor
BLOB
FW-Update
Identification and Diagnosis
SSC, type 0 Generic Profiled Sensor
Teach Channel
Teach-in Single Value
Teach-in Two Value
Teach-in Dynamic
Transducer Disable
Length
Data
Type
1
12 bytes
UINT16[]
20 bytes
Data
Default
Storage
n/a
–
english
103