Before performing any maintenance, disconnect the appliance from the mains.
FAILURE TO PERFORM REGULAR MAINTENANCE, at least on a seasonal basis, could lead to poor functionality.
Any problems resulting from lack of maintenance will immediately void the warranty.
WEEKLY CLEANING
Cleaning should be carried out with the aid of a vacuum cleaner (see optional page. 45).
Operation to be carried out when the boiler is cold.
Never vacuum hot ashes as this would damage your vacuum cleaner.
Suction clean the door.
Open the small door and remove and empty the ash tray (Fig. A-1) vacuum the re bed.
Remove the front tile (Fig. B-2).
Vacuum the crucible or scrape it with the spatula provided clear any obstructions from the holes on all sides after removing the
front plate ( g. C -3).
Clean the spark plug
Remove the inspection plugs on both sides of the hearth and vacuum the crucible (Fig. D-4).
Move the swabs (*) by moving the lever from the top down (see g. E) after having removed it from its housing.
Following a period in which the boiler has been inactive and in any case at least every month empty the pellet storage tank and
vacuum the bottom.
SEASONAL CLEANING
seasonal cleaning, outlined here below, are listed.
Clean the boiler internally and externally
Carefully clean the heat exchange tubes
Carefully clean and remove dirt from the combustion chamber and the relative compartment
Clean the motors verify mechanical and clam loosening
Clean smoke channel (replace seals on pipes) and smoke extraction fan chamber
Check the expansion tank
Check and clean the circulator
Check the sensors
Check and if necessary replace the clock battery on the control board
Clean inspect and scrape any residue from the ignition resistance compartment and if necessary replace it
Clean/check the Synoptic Panel
Visually inspect the electrical wires connections and power cable
Clean the pellet hopper and check loosening of the feed screw - gear motor assembly
Check and if necessary replace the door seal
Functionality test: load the feed screw ignite let it run for 10 minutes and shutdown
If maintenance if not implemented, the warranty will be rendered null and void.
If the boiler is used very often, it is recommended to clean the smoke channel every 3 months.
When maintenance is implemented in the smoke channel, consider UNI 10847/2000 Individual chimney installations for
The chimney stacks and smoke ducts to which solid fuel appliances are connected should be cleaned once a year (verify
whether in there are regulations in force in your country regarding this).
In the event of such an occurrence proceed as follows:
- do not extinguish with water
- empty the pellet storage tank
- contact the Dealer before re-starting after such an incident.
MAINTENANCE
(see illustration on next page)
(implemented by the dealer)
- 40
-