Herunterladen Inhalt Inhalt Diese Seite drucken

Transport And Storage; Shipping; Transport Inspection; Storage - Wilo -Stratos GIGA2.0-I Einbau- Und Betriebsanleitung

Vorschau ausblenden Andere Handbücher für Wilo-Stratos GIGA2.0-I:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

en
5

Transport and storage

5.1

Shipping

5.2

Transport inspection

5.3

Storage

Fig. 5: Turning the shaft
136
Blind flanges for twin-head pump housing
Installation aid for mechanical seal (incl. mounting bolts)
CIF module PLR for connecting to PLR/interface converter
CIF module LON for connection to the LONWORKS mains network
CIF module BACnet
CIF module Modbus
CIF module CANopen
CIF module Ethernet Multi-protocol (Modbus TCP, BACnet/IP)
Differential pressure sensor DPS 2 ... 10 V
Differential pressure sensor DPS 4 ... 20 mA
Temperature sensor PT1000 AA
Sensor sleeves for the installation of temperature sensors in the pipe
Stainless steel screwed connections differential pressure sensor
For a detailed list, consult the catalogue and spare parts documentation.
NOTICE
CIF modules and Wilo-Smart Connect Module BT may only be plugged in
when the pump is de-energised.
The pump is secured to a pallet ex works, packaged in a box and protected against dirt and
moisture.
Check delivery immediately for damage and completeness. Defects must be noted on the
freight documentation! Defects must be notified to the transport company or the manu-
facturer immediately on the day of receipt of shipment. Subsequently notified defects can
no longer be asserted.
Only remove the outer packaging at the place of utilisation to ensure that the pump is not
damaged during transport.
CAUTION
Damage due to incorrect handling during transport and stor-
age!
Protect the product from moisture, frost and mechanical damage during
transport and temporary storage.
Leave stickers on the pipe connections so that no dirt and other foreign matter can get into
the pump housing.
To avoid scoring at the bearings and sticking, turn the pump shaft once a week using an Allen
key (Fig. 5).
If a longer storage time is required, contact Wilo for preservation measures.
WARNING
Risk of injury due to incorrect transport!
If the pump is transported again at a later date, it must be packaged so
that it cannot be damaged during transport. Use the original packaging for
this, or choose equivalent packaging.
Damaged transport lugs can break off and cause considerable personal in-
jury. Check the transport lugs before use for damage and secure fixation.
Installation and operating instructions • Wilo-Stratos GIGA2.0-I, Wilo-Stratos GIGA2.0-D • Ed.02/2022-07

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Wilo-stratos giga2.0-d

Inhaltsverzeichnis