Herunterladen Inhalt Inhalt Diese Seite drucken

Setup And Calibration; Transporting The Machine; Electrical Connection - Scheppach 5905109901 Original Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für 5905109901:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

10. Setup and calibration

• Make sure that the machine is stable on solid ground during assembly.
• The workplace must be well lit.
• The area around the machine must be free of trip hazards.

11. Transporting the machine

Swivel frame lock
• To transport the swivel log saw, latch the swivel lock in position (1).
• Transport the swivel log saw by the handle (2).
• When transporting the rocking frame circular saw with petrol engine, insert the transport handle (3) through 2 loops
and, for safety, slightly turn it, and lift and transport it using the transport handle.
1
2
3
12. m Electrical connection
The electrical motor installed is connected and ready for operation. The connection complies with the applicable VDE
and DIN provisions. The customer's mains power connection as well as the extension lead used must also comply with
these regulations and the local regulations.
Check the electrical connection cables for damage regularly. Ensure that the connection cables are disconnected from electri-
cal power when checking for damage.
Electrical connection cables must comply with the applicable VDE and DIN provisions. Only use connection cables with
the marking "H 07 RN".
The printing of the type designation on the cable is mandatory.
Damaged electrical connection cables
Insulation damage often occurs on electrical connection lines.
Causes are:
Pressure points, where connection cables are passed through windows or doors.
Kinks where the connection cables have been improperly fastened or routed.
Places where the connection cables have been cut due to being driven over.
Insulation damage due to being ripped out of the wall outlet.
Cracks due to the insulation ageing.
Such damaged electrical connection cables must not be used and are life-threatening due to insulation damage!
3-phase motor 400 V / 50 Hz
Mains voltage 400 Volt / 50 Hz.
Mains power connection and extension leads must be 5-core = 3 P + N + SL. - (3/N/PE).
Extension cables must have a minimum cross section of 1.5 mm² (≤ 25m).
Extension cables must have a minimum cross section of 2.5 mm² (> 25m).
GB | 25
www.scheppach.com

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis