Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning The Machine; Batteries; Regular Maintenance; Recommended Spare Parts - Sprintus Torana Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Check that the brushes are leveled (check brushes
and grinding wheels for irregular wear).
Only Sprintus recommended accessories should be
used. Other products may affect safety.
8.6
CLEANING THE MACHINEN
To clean the outside of the machine, use a sponge
or cloth. If necessary, a soft brush can be used to
remove stubborn dirt.
The use of steam cleaners, water hoses or
high-pressure cleaners is prohibited.
8.7

BATTERIES

Maintenance-free gel batteries are used on your
Torana. Interventions on the batteries must not
be made. Only use genuine Sprintus batteries /
battery chargers. Gel batteries only reach their
full capacity after a few cycles. Gel batteries have
NO memory effect. The devices can and should
be recharged after short periods of use. Deep dis-
charging damages the battery. Using the machine
until the battery is empty should be avoided. If
it's done anyway, charge the battery immediately
afterwards. If the machines are not in use, the
batteries should be recharged every 2 months in
order to avoid deep discharging. In cold ambient
temperatures, this time period should be shorter.
8.8

REGULAR MAINTENANCE

For all procedures described here, refer to the
detailed instructions and warnings in the relevant
sections of this manual.
8.9

RECOMMENDED SPARE PARTS

It is recommended to always have enough con-
sumables available and to perform maintenance
work on a regular basis.
9

CLEANING / MAINTENANCE

see table on page 33
9.1
ERRORS
9.1.1

THE MACHINE DOES NOT WORK

 The battery connector is disconnected or improperly
connected to the main cable connector.
 Connect both connectors correctly.
 The machine is charged.
 End charging.
 The batteries are empty.
 Charge batteries.
 The brushing or suction motor is overheated.
    T he motors have thermal protection fuses and
switch off in case of overheating. Allow the machine
to cool down for 30 minutes. An overly rough floor
or aggressive brushes / pads can cause the brush
motor to overload. When switching off the suction
motor, remove any obstructions.

9.1.2 ERROR DISPLAYS ON THE DISPLAY

    Brush LED permanently on:
      I f the brush does not turn, check whether some-
thing has become wrapped around the drive shaft.
Remedy the cause of the error.
    Suction motor LED is flashing:
      T he suction motor is not running. Check the suction
motor and make sure that the waste water tank is
empty.
      B rush LED and suction motor LED are flashing rap-
idly:
      T he thermal protection fuse of the brush motor
or the suction motor has been triggered. Check
whether something has become wrapped around
the drive shaft. Check the suction motor and make
sure that the waste water tank is empty.
 LED 38 flashes (with battery version):
LED 32A flashes (with cable version)
 A power switch (2) has been activated and must
first be released.
9.1.3 THE BRUSH DON'T ROTATE
    The brush motor switch was not switched on.
    Press the switch to switch on the brushes.
      T he thermal protection switch of the brush motor
has been activated; the motor is overheating.
      T he brush motor has thermal protection fuses and
switches off in the event of overheating. Allow the
machine to cool down for 30 minutes. An overly
rough floor or aggressive brushes / pads can cause
overloading.
      T he relay of the motor or the brush motor is defective.
    Have it replaced by a specialist.
9.1.4 NOT ENOUGH OR TOO MUCH
DETERGENT
 The solution tank is empty.
 Fill the solution tank after emptying the waste water
tank.
 The brushes or the machine are not switched on.
 Switch on the brushes.
 The fresh water regulation is closed or almost closed.
 Adjust the water supply as desired.
 The fresh water filter is clogged.
 Fresh filter.
 The hoses of the water supply are blocked.
 Remove blockage.
 The solenoid valve has blown.
 Have the solenoid valve replaced by a specialist.

9.1.5 NO SUCTION OPERATION

 The suction hose is not connected to the squeegee.
 Connect correctly.
 The suction hose is clogged.
 Repair the blockage.
 The suction motor is switched off.
 Turn on the motor.
 The waste water tank is full.
 Empty the tanks.
31

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis