Chapter 7. Ordinary maintenance

7.4. Replacement of the cover gasket

When the cover gasket (17) is worn out, replace it.
This will improve the efficiency of the machine and increase its
speed rate. Replacement is very easy. After having removed the
gasket which has worn out, clean its seat and insert the new gasket
in a linear way. Make sure its ends are joined. Leave no opening
which might prevent the product from being properly vacuum-
packed.

7.5. Cleaning machine

To clean the Plexiglas cover (18), clean both the outer and
the inner side with water and soap only.
Never use detergents or solvents which might damage the
cover (18) and reduce its transparency as well as its
resistance.
Check the state of the cover on a regular basis, it must in good
condition, completely clean, and must not display any yellowing or
increase in opacity.
If any of the above defects are observed, replace the cover.
The Plexiglas cover must be replaced ever 10 years!
Use normal detergents for stainless steel to clean the case and the
internal tank.

7.6. Vacuum pump maintenance

It is very important to regularly service the pump to ensure extended and correct operation. The following activities are
essential for correct maintenance.

7.6.1. Changing the oil and the pump filter

The oil level and oil quality must be checked at least once a week.
The oil inspection plug (22) serves this purpose. Fill up the oil level if
it is too low. Replace the oil if it is turbid.
Take care to replace the oil filter before adding the new oil.
Follow the instructions you can find on the pump manual in order to
change the oil and the vacuum pump filter.
However, oils of the VG type shall be used in compliance with the
DIN 51506 standards.
The oil you have replaced must be eliminated
according to the procedures established by the laws
in force in the country the equipment has been
installed.
(20) Oil discharge plug (to completely replace old oil)
(21) Oil filling plug
(22) Oil inspection plug
mod. MV26 X
mod. MV31 X
mod. MV35 X
22