Herunterladen Inhalt Inhalt Diese Seite drucken

Abicor Binzel iCAT Betriebsanleitung Seite 58

Roboterhalterung
Vorschau ausblenden Andere Handbücher für iCAT:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
9 Maintenance and cleaning
9.2 iCAT Cleaning the ABIROB
1
14
13
1
O-ring 36x2
2
Gas duct
3
Set screw
®
4
iCAT ABIROB
W
5
4 O-rings 3 x 1.5
Fig. 16
Cleaning the iCAT ABIROB
EN - 26
®
W
2
12
11
6
2 O-rings 7 x 1.5
7
2 compression sleeves
8
2 compression springs
9
2 balls
10 Screw
®
W
1 Pull off retaining ring (13) together with bellows (14).
2 Check the O-ring (1) for wear and replace it if necessary. Before replacing,
grease the O-rings (1) with sealing grease (included in the scope of
delivery).
3 Remove screw (10), washer (11) and fastening screw (12) and clean them
together with compressed air.
4 Blow compressed air through the bores.
5 Remove balls (9), compression springs (8) and compression sleeves (7),
check them for damage and replace them if necessary.
WARNING
Risk of injury
Serious injuries caused by parts swirling around.
• When cleaning with compressed air, wear suitable protective clothing, in
particular safety goggles.
6 Clean the iCAT ABIROB
3
10
11 Washer
12 Fastening screw
13 Retaining ring
14 Bellows
®
W (4) with compressed air.
4
9
iCAT
5
6
7
8

Werbung