• Use the device only in dust-free conditions, otherwise treatment could be compromised.
• The casing of this unit is not protected against the penetration of liquids. Do not wash the device under running
water or submerge in water. Keep away from splashing water or other liquids.
• Do not expose the device to particularly extreme temperatures.
• Do not place the device near sources of heat, in direct sunlight or in excessively hot rooms.
• Do not obstruct or put objects into the filter or its related housing in the device.
• Never obstruct the air vents located on both sides of the device.
• Always use it on a rigid surface that is clear of obstacles.
• Make sure there is no material obstructing the air vents before each use.
• Do not put any objects in the air vents.
• Repairs, including the replacement of the supply cord, are to be carried out by FLAEM authorised personnel only,
by complying with the information provided by the manufacturer. Unauthorized repairs will void the warranty
and may represent a danger to the user.
• The average expected duration for the compressor series are: F400: 400 hours, F700: 700 hours, F1000: 1000
hours, F2000: 2000 hours.
• WARNING: Do not modify this device without authorisation from the manufacturer.
• The Manufacturer, the Vendor and the Importer shall be held responsible for safety, reliability and performance
only if: a) the device is used in compliance with the instructions for use b) the wiring where the device is being
used is in compliance with safety regulations and current laws.
• Interactions: the materials used in contact with medication have been tested with a vast range of medications.
However, in view of the variety and continuous evolution of pharmaceuticals, interactions cannot be ruled out.
We recommend using the medication as soon as possible once it has been opened and preventing prolonged
exposure in the nebuliser cup.
• The manufacturer must be contacted about any problems and/or unexpected events concerning operation and
for any clarifications on use, maintenance/cleaning.
• Interactions: The materials used in the medical device are biocompatible in accordance with the provisions of
Directive 93/42 EC and subsequent amendments. However, the possibility of occurrence of allergic reactions
cannot be entirely excluded.
• The amount of time required between preservation conditions and use is approximately 2 hours.
INSTRUCTIONS FOR USE
RF6 Basic
NEBULISER
2
Before each use, clean hands thoroughly and clean the device as described in the section on "CLEANING
SANITISATION DISINFECTION". During use, it is advisable to protect yourself from any dripping. It is
recommended that each person use their own nebulizer cup and accessories to prevent risk of infection due
to contamination.
This device is suitable for the administration of medical substances and not, for which the administration
via aerosol is foreseen; these substances are to be in any case prescribed by the Doctor. In case of too thick
substances, the dilution with a suitable physiological solution could be needed, according to the medical
prescription.
1. Plug the power cord (A6) into the socket (A5) and plug the power cord into a power socket corresponding to the
voltage of the unit. This must be positioned so that it is not difficult to make the disconnection from the mains.
2. Assemble the nozzle as indicated in the "Connection diagram" in point C1.2 Insert
the complete nozzle in the bottom part (C1.1). Insert the Upper ventilation cover
(C1.4) in the upper part (C1.3) as shown in the "Connection diagram" in point C1.
3. Pour the medication prescribed by the physician into the lower part (C1.1). Close
the nebuliser by turning the upper part (C1.3) clockwise.
4. Connect accessories as indicated in the "Connection diagram" on the cover.
5. Sit comfortably holding the nebuliser in your hand, place the mouthpiece onto
your mouth or alternatively use the nose piece or mask. Should you opt for the
mask accessory, place it on your face as shown in the picture (with or without
using the elasticated strap).
The cap (C1.4) provided with the nebuliser RF6 Basic
"standard mode"
for optimum delivery and mini-
mum waste of medication
makes it possible to deliver the medication in 2 modes:
2
"high speed mode" for a quicker
treatment