Installation
6
Installation
!
WARNING! Electrical shock!
Failure to obey these instructions could result in death or serious injury.
•
When positioning the device, ensure the supply cord is not trapped
or damaged.
•
Do not locate multiple portable socket-outlets or portable power
supplies at the rear of the device.
!
CAUTION! Health hazard
To avoid a hazard due to instability of the device, it must be fixed in
accordance with the instructions.
The cooling device is designed for free-standing installation, but it can also be
installed in a built-in cabinet. To ensure satisfactory operation and maximum cooling
efficiency the following installation conditions have to be fulfilled.
•
The cooling device must be levelled carefully to ensure proper function.
•
The clearance between the cooling device's back and the wall should be 20 mm
or more.
Ventilation must be provided as shown in alternatives A, B, C or D (fig. 2,
•
page 3).
•
The ventilation duct must at least measure 105 mm x the width of the cooling
device.
The entire cooling unit must project into the ventilation duct as shown (fig. 2,
•
page 3). Other parts of the device may not project into the ventilation duct.
•
Air passing through the ventilation duct must not be preheated by any source of
heat.
•
Ventilation grills, if used, must have openings of at least 200 cm².
•
Moisture will condense on the door of the glass door version, when the ambient
humidity is above 65 % in 25 °C ambient temperature.
•
The cooling device must be fixed. Use screws of an appropriate length and insert
them through the device feet (fig. 3, page 3).
•
The socket outlet for the mains connection must be freely accessible.
6.1
Changing the decorative plate
To change the decorative plate proceed as shown in fig. 4 to fig. 7 on page 4.
16
RH4xxLD, RH4xxLG
EN