Herunterladen Inhalt Inhalt Diese Seite drucken

Alarm Indications - Cardin Elettronica SL Serie Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für SL Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 134

ALARM INDICATIONS

Whenever an error effecting the normal operation of the installation is detectedit will be indicated throug a series of alarm signals which
appear in real time on the digital display:
PROGRAM
TB
FI
TA TD
Flashing on the display. You have to enter the programming mode to program the system.
FS CP
TC TAL
TB
FI
TA TD
During normal operation it indicates that the automatic repositioning procedure is about to take place. In this case any
FS CP
TC TAL
commands received (TA, TC, TAL or TD) will automatically start this procedure.
OUT OF POS
STOP PROG
This happens when an N.C. contact is activated (FI, FS, CP) during encoder programming or automatic repositioning. Once
TB
FI
TA TD
the passive state of the security devices has been reset the gate will start moving again automatically. It also happens if
FS CP
TC TAL
a blackout occurs during programming.
AUTO PROG
Safety device test error. Check the condition of the safety devices and make sure that the alarm cuts in when an obstacle
TB
FI
TA TD
interferes with the beam (indication white characters on a black background). In case of anomalies replace the damaged safety
FS CP
TC TAL
SAFETY ERROR
device or bridge the contact and deactivate the safety test (option menu)
This occurs when the programmer sends a command to the motor and nothing happens (motor doesn't move). Check the Faston
TB
FI
TA TD
connections of the motor and the condition of the fuses 'F1', 'F3' and then give another opening or closing command. If the
FS CP
TC TAL
ERROR MOT
motor still doesn't move you are faced with either a mechanical problem or a problem with the programmer.
TB
FI
TA TD
Encoder count error. If this error occurs during normal motor operation it means that there is a problem with the encoder
FS CP
TC TAL
signal. Check the relative connections and carry out automatic repositioning.
ERROR ENC