AF09(Z)B...38(Z)B, NF(Z)B22E...80E, CA4, CAL4, CAT4, CC4
1SBC101037M6801 - 02/16
Contactors AF..B, contactor relays NF..B and accessories
Schütze AF..B, Hilfsschütze NF..B und Zubehör
Contacteurs AF..B, contacteurs auxiliaires NF..B et accessoires
Kontaktorer AF..B, reläkontaktorer NF..B och tillbehör
Contattori AF..B, contattori ausiliari NF..B e accessori
Contactores AF..B, contactores auxiliares NF..B y accesorios
AF..B
B
AF09(Z)B...16(Z)B-30-01
AF09(Z)B...16(Z)B-30-10
AF09(Z)B..16(Z)B-40-00
AF09(Z)B..16(Z)B-22-00
NF(Z)B22E ...40E
-10
CA4/CC4
-01
CA4-40/22/31/04
CAL4-11
TF42
AF09(Z)B-30..
... AF16(Z)B-30..
Pos
NF(Z)B40E
. 2
AF09(Z)B...16(Z)B-30-10
AF09(Z)B...16Z)B-40-00
AF26(Z)B...38(Z)B-30-00
Pos
. 4
AF09(Z)B...16(Z)B-30-01
AF26(Z)B...38Z)B-40-00
Pos. 3
AF09(Z)B...38(Z)B-22-00
NF(Z)B31E, NF(Z)B22E
NF(Z)B44E... NF(Z)B80E
Pos. 1
A1
Uc
24V 50/60Hz
Uc
20V DC
NFB.., AF09B...38B,
A2
NFZB.., AF09ZB...38ZB
devices comply to
Energy
GB21518
efficiency
...V 50/60Hz
level
AF09...38(Z)B-30..
24 ... 250V
2
AF09...16(Z)B-30..
250 ... 500V
2
AF26...38(Z)B-30..
2
AF09(Z)B...16(Z)B
M 3,5
Ø 5,5
3 & 4-pole
1,5 N.m
AF26(Z)B...38(Z)B
M 4
Ø 6,5
3-pole
2,5 N.m
AF26(Z)B...38(Z)B
M 4,5
Ø 5,5
4-pole
2,5 N.m
AF09...16(Z)B-30-10
AF09...16(Z)B-30-01
M 3,5
Ø 5,5
1,2 N.m
NF(Z)B...
M 3,5
AF09(Z)B ... 38(Z)B
Ø 5,5
1,2 N.m
NF(Z)B...
NF(Z)B22E...NF(Z)B40E
AF09(Z)B...16(Z)B
AF26(Z)B...38(Z)B 3-pole
AF09(Z)B...38(Z)B,
AF26(Z)B...38(Z)B 4-pole 101 3.98"
NF(Z)B22E...NF(Z)B80E
2 0.08"
2 0.08"
45 1,77"
ABB France
3, rue Jean Perrin
69680 Chassieu / France
www.abb.com/lowvoltage
NF..B
NF
B
NF(Z)B44E...80E
CAL4-11
CAL4-11
CAT4-11
CAL4-11
+30°
-30°
+ max 6 aux contacts / 4NC
+ max 6 aux contacts / 3NC
CA4-04
+ max 1x CAL4-11
Pos. 1 ± 30°
According to UL60947-4-1, for use on a circuit capable of delivering not more than the
max. symmetrical amperes at the max. voltage shown in the table below.
WARNING : if opening of BCP, controller shall be examined and replaced if damaged.
AF09, AF12
Max Short-
max Fuse
circuit at
Holding
480V, 600V
30A/RK5 30A/J
(kA)
power
5
100
VA
AF09/12/16
Max Short-
3,5
circuit at
Circuit-Breaker
480V, 600V
XT2V125 + TM60
5
(kA)
5,5
L
mm²
mm²
mm²
mm
2 x 0,75...2,5
2 x
2 x
L = 10
1 x 0,75...4
1...6
0,75...6
2 x
2 x 1,5...4
2 x
L = 14
1,5...10
1 x 1,5...10
2,5...10
2 x
2 x
2 x
L = 12
1,5...16
1,5...16
1,5...16
2 x
2 x 0,75...1,5
2 x
L = 10
0,75...2,5
1 x 0,75... 2,5
1...2,5
2 x
2 x
2 x 0,75....1,5
L = 10
1...2,5
0,75...2,5
1 x 0,75... 2,5
A
B
mm inch
mm inch
77 3.03"
71 2.80"
NF(Z)B44E...NF(Z)B80E 110,5 4.35"
86 3.39"
80 3.15"
95 3.74"
A
B
5.5
0.22"
5.5 0.22"
5.5 0.22"
10 0.39"
AF26(Z)B...38(Z)B-30-00
CAL4-11
-10
CA4/CC4
-01
CA4-40/22/31/04
AF26(Z)B-30..
TF42
... AF38(Z)B-30..
NF(Z)B40E
AF09(Z)B...16(Z)B-30-10
AF09(Z)B...16(Z)B-40-00
AF26(Z)B...38(Z)B-30-00
NF(Z)B31E, NF(Z)B22E
AF09(Z)B...16(Z)B-30-01
AF26(Z)B...38(Z)B-40-00
AF09(Z)B...38(Z)B-22-00
NF(Z)B44E... NF(Z)B80E
Pos. 5
AF26
AF16
Max Short-
circuit at
max Fuse
max Fuse
480V, 600V
60A/RK5
60A/J
60A/RK5 60A/J
(kA)
5
100
5
100
AF26/AF30/AF38 AF26/AF30/AF38 AF26/AF30/AF38
Max Short-
Circuit Breaker
circuit at
T4V250 + TM250
480V (kA)
35
10
600V (kA)
25
Assembly - Anbau - Montage - Montering
Montaggio - Montaje -
L
L
mm
mm
_
L < 9,6
_
L < 12,5
_
2
L = 5,5
H = 2 x 6,8
_
L < 9,6
Disassembly - Abbau
_
Démontage - Demontering
L < 8
Smontaggio - Desmontaje
_
-
L < 8
A
B
Acc. to UL60947-4-1, min. enclosure for :
mm inch
mm inch
AF09(Z)B...AF16(Z)B, NF(Z)B... : 180 x 130 x 150mm
71 2.80"
AF26(Z)B...38(Z)B 3-pole : 255 x 180 x 175mm
AF26(Z)B...38(Z)B 4-pole : 180 x 130 x 175mm
A
10 0.39"
B
5.5 0.22"
Operating instructions
Betriebsanleitung
Notice d'instruction
Instruktion
Istruzioni tecniche
Instrucciones de empleo
AF26(Z)B...38(Z)B-40-00
AF26(Z)B...38(Z)B-22-00
CAT4-11
CAL4-11
+ max 6 aux contacts / 3NC
CA4-04
+ max 6 aux contacts / 2NC
CA4-04
+ max 1x CAL4-11
NF(Z)B..,
AF09(Z)B...38(Z)B
1
AF30
AF38
max Fuse
max Fuse
100A/RK5 100A/J
100A/RK5 100A/J
5
100
5
100
Circuit Breaker
Circuit Breaker
XT2V125 + TM100
XT1H125 + TM100
65
65
42
-
-
35 mm
3
EN/IEC 60715
NF(Z)B.., AF09(Z)B...38(Z)B + LDC4
2
35 1.38"
2 x
ø 4.2 0.17"
M4 8-32 UNC
1
LDC4
5 0.20"
CAL4-11
-10
CA4/CC4
-01
CA4-40/22/31/04
CAT4-11
Uc
A1
A2
A1
A2
2
Uc
NF(Z)B..,
AF09(Z)B...38(Z)B
4
CLIC !
A1
A2
Uc
A1
A2
2
CLIC !

Werbung

loading

Inhaltszusammenfassung für ABB CAL4

  • Seite 1 AF09(Z)B...38(Z)B, NF(Z)B22E...80E, CA4, CAL4, CAT4, CC4 1SBC101037M6801 - 02/16 Contactors AF..B, contactor relays NF..B and accessories Operating instructions Betriebsanleitung Schütze AF..B, Hilfsschütze NF..B und Zubehör Notice d'instruction Contacteurs AF..B, contacteurs auxiliaires NF..B et accessoires Instruktion Kontaktorer AF..B, reläkontaktorer NF..B och tillbehör Istruzioni tecniche Contattori AF..B, contattori ausiliari NF..B e accessori...
  • Seite 2 134,5 5.3" 126,5 4.98" NF(Z)B, AF09(Z)B...38(Z)B + CAL4-11 Warning ! Hazardous voltage! The operation, installation and servicing of this appliance must be carried out by a qualified electrician applying the relevant rules of the art, installation standards and safety regulations. Before operating the contactors, check that control voltage complies with the data of the coil. Connection to other control voltage can destroy the coil. Do not touch live parts.