The controller must be installed at a distance of 40 - 80 mm from the wall. In
order to avoid hazards for children, the towel rail should be installed in such a
way that its lowest part is at least 600 mm from the floor.
② -
ZONE 2
(protection IPX4)
③ -
ZONE 3
(protection IPX1)
Do not insert metal objects or fingers, even temporarily, into the area where
the controller is connected to the towel rail.
Do not cover, even partially, the controller.
Check electrical hi pot on all controls after fitting to the radiator according to
the instructions in Appendix A of EN60335-1.
In the event of faults or anomalies, or if the plastic parts of controller are
damaged, disconnect from the mains, switch off the omnipolar switch
immediately, and contact the seller.
The supply cord cannot be repaired. If it is damaged, contact the seller to
replace the whole controller; do not try to modify or repair controller. Do not
attempt to remove the buttons or display: electric shock hazard; there is also
a danger of water penetrating and damaging electrical components.
Do not knock controller. Always handle with care and do not leave the device
in wet areas.
Fig. 1: Bathroom zone classification
SAFETY INFORMATION
4