Herunterladen Inhalt Inhalt Diese Seite drucken

Specifications; Outline And Dimensions - Siemens ST-H Serie Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 19

Specifications

Measurement Range
Pressure
Supply Source
Frequency
Beam Angle
Weight*
Separation
Environmental
Location
Altitude
Ambient Temperature
Construction
Housing
Mounting
Cable
Options
Approvals
*
Approximate shipping weight of transducer with standard cable length.
** For chemical application check compatibility of EFTE and epoxy, or mount joint external to process.
*** Performance available upon request.

Outline and Dimensions

1" NPT conduit
thread
2" NPT, 2" BSP , or PF2
mounting thread (process
connection)
87 mm
(3.4")
Page EN-4
ST-H Transducer
0.3 - 10 m (1 - 33 ft)
vent to atmosphere
transducer shall only be supplied by a Siemens Milltronics
certified controller
43 KHz
12°
1.4 Kg (3 lb)
365 m (1200 ft) from transceiver
indoor/outdoor
2000 m (maximum)
- 20 to 60 °C (-5 to 140 °F)
EFTE base and lid (epoxy fitted joint)**
2" NPT, 2" BSP , or PF2 process connection
2 wire twisted/shielded, 0.5 mm
• flange adapter, refer to associated instructions
• submergence coupling, refer to associated instructions
CE***, CSA, FM, BASEEFA / CENELEC, ATEX
ST-H Transducer – OPERATION MANUAL
2
(20 AWG), PVC jacket
119 mm (4.7")
74 mm (2.9")
82 mm (3.2")
7ML19985QK81

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis