10-286 / 10-386
2.4.4. Dome camera module (10-386)
Dome camera
1
Integrated two-wire video transmitter 10-498
2
Terminals bus and video
3
Technical data:
Power supply
Housing
Lens
Camera screen
H x W x D
Weight
Allowable ambient temperature
Input current in standby
Max. input current
Video signal
Camera type
Resolution
Light sensitivity
Lens
Focal point
Angle
Cabling
Note: Recommended mounting height of the camera: 1.60 m to 1.70 m.
Short description:
• The high-resolution image sensor ensures that all image points can be optimally adjusted.
• The output level of the 2-wire video signal from -3 dB to 9 dB is manually adjustable.
3. INSTALLATION
3.1. Cabling
Which type of cable should I use?
The external audio unit 10-286 is wired with a 3-wire twisted cable for optimal quality. The diameter of the wires will determine the maximum distance between
the power supply and the internal or external unit. The table below provides an overview of the maximum distance per type of cable.
10-286
Cable diameter
0,5 mm (UTP)
0,6 mm (bv. TPVF)
0,8 mm (bv. SVV, TVVF, JYSTY, ...)
The external video unit 10-386 is wired with a 6-wire twisted cable for optimal image quality. The diameter of the conductors determines the maximum distance
that can be bridged between the power supply and the internal video unit, or between the power supply and the external video unit. The table below provides
an overview of the maximum distance per type of cable.
36
+ 24V ± 8 % (power supply and control device), +26 V /
DC (from P-conductor)
Anodized aluminium
Acrylic glass
Plastic
125 x 105 x 42 mm
455 g
-10°C to +50°C
I(P) = 0 mA
I(P) = 60 mA
I(P) = 60 mA
Symmetric 1Vss FBAS
Black Light Compensation (BLC), Auto Gain Control (AGC),
Auto White Balance (AWB)
0,8 cm (1/3 inch)
700 lines (TVL)
0,002 lux / F 1,2
F1,2, board lens
f = 3,6 mm
± 90° diagonally
6-wire cabling
Maximum distance
100 m
160 m
280 m
10-361
2
3
1
V2
V1
M
P
b
a