en
60 | TCE 4460-TCE 4465 | Maintenance
5.3.3
Topping up oil in oil atomizer
1. Unfasten the compressed air connection.
2. Unscrew the cap (A) of the oil tank at the oil atomizer.
3. Top up the oil (see Tab. 6).
Fig. 62:
Topping up oil
5.3.4
Setting lubricating oil flow
! Check whether all compressed air connections have
been made. Set the lubricating oil outflow rate at the
filter assembly.
Use a screwdriver to set the screw (A) such that one drop
of oil emerges for every 2 opening and closing operations
of the bead breaker arm.
Fig. 63:
Setting lubricating oil flow
|
1 695 100 278
2013-12-03
5.4
Spare and wearing parts
Designation
Mounting head sticker
Voltage sticker
Unseating unit sticker
Tilting column sticker
Soft plastic jaws for 30" clamping plate
Bolt for bead breaker blade
Mounting head
Plastic guard for mounting finger (5x)
Guard for mounting head
Protective cover for sliding arm
Bead breaker blade
Front unseating unit support
Rear unseating unit support
Tab. 6:
Spare and wearing parts
Order number
Robert Bosch GmbH