Herunterladen Inhalt Inhalt Diese Seite drucken

Bosch D-tect 150 Professional Originalbetriebsanleitung Seite 24

Vorschau ausblenden Andere Handbücher für D-tect 150 Professional:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 7
OBJ_BUCH-844-005.book Page 24 Tuesday, July 14, 2009 9:12 AM
24 | English
Changing the Operating Modes
Changing between different operating modes is
possible with selection buttons 10 and 12.
– Briefly press selection button 10 to select
the next operating mode.
– Briefly press selection button 12 to select
the previous operating mode.
By selecting the operating modes, you can adapt
the measuring tool to different wall materials
and suppress insignificant objects (e.g. hollow
spaces in brickwork). The current setting is al-
ways shown in the operating-mode indication h
of the display.
Universal Mode (default setting)
"Universal mode" is suitable for most applica-
tions in brickwork or concrete. Plastic and metal
objects as well as electrical wiring are dis-
played. Hollow spaces in brickwork or empty
plastic pipes with a diameter of less than 2 cm
are possibly not displayed. The maximum meas-
uring depth is 6 cm.
Concrete Deep
"Concrete deep" mode is particularly suitable
for concrete applications. Reinforcing steel,
plastic and metal pipes, as well as electrical
wiring are displayed. The maximum measuring
depth is 15 cm.
Panel Heating
The operating mode "Panel heating" is parti-
cularly suitable for detecting metal, metal-com-
posite and water-filled plastic pipes, as well as
for electrical wiring. Empty plastic pipes are not
displayed. The maximum measuring depth is
8 cm.
Drywall
The operating mode "Drywall" is suitable for
finding wooden beams, metal framing and elec-
trical wiring in drywalls (wood, gypsum board,
etc.). Filled plastic pipes and wooden beams are
displayed identically. Empty plastic pipes are
not detected. The maximum measuring depth is
6 cm.
1 609 929 R51 | (14.7.09)
Hollow Block
The operating mode "Hollow block" is suitable
for walls with many air pockets. Metal objects
and "live" conductors are detected. Plastic
tubes and voltage-free conductors are not de-
tected. The maximum detection depth is 6 cm.
Changing the Display Modes
Note: Changing the display modes is possible in
any operating mode.
To switch from the standard start display to rule
mode, press and hold selection button 10 or 12.
?
N
8.8 cm
S
20.1 cm
18
19
20
21
cm
10cm
20cm
Prev.
Concrete deep
In the example, rule mode shows the same situ-
ation as in figure D: Three steel bars equally
apart. In rule mode, the clearance between the
detected object centres can be determined.
The measuring distance covered from the start-
ing point (in the example 20.1 cm) is displayed
under the indication of the allowable drilling
depth l.
The three objects are displayed as rectangles in
the small rule above the operating-mode indica-
tion h.
Note: Both the indication of the allowable drill-
ing depth l as well as the material property m re-
fer to the object pictured black in the sensor.
To return to the standard start display, briefly
press selection button 10 or 12.
Note: Only the display is reset, not the measuring
mode!
22
23
30cm
40
Next
Bosch Power Tools

Werbung

Inhaltsverzeichnis
loading