BTL7-A/E1 _ 0-M _ _ _ _ -K(8)-SA262-K _ _ /F _ _
Micropulse Transducer - Rod Style
6
Calibration procedure (continued)
6.3
Calibration procedure overview
6.3.1
Teach-in
The factory set null point and end point is replaced by a
new null point and end point. The null point and end point
can be set separately, the output gradient changes.
The detailed procedure for teach-in is described
on page 15.
Steps
► Move magnet to the new null position.
► Read new null point by activating the programming
inputs.
⇒ The current end point remains the same.
New null point
Fig. 6-2:
Reading new null point
► Move magnet to the new end position.
► Read new end point by activating the programming
inputs.
⇒ The current null point remains the same.
www.balluff.com
Fig. 6-3:
Reading new end point
Inverting
► The gradient of the output can be inverted by activating
Before
the programming inputs.
⇒ For example, a rising output gradient is changed to
After
a falling gradient.
Before
After
New end point
english
13