6.2.7 Cable technical specifications
Depending on the type of illuminator (Low or
High Power) and on the supply voltage, apply the
following maximum lengths for the power cables (to
be connected to the black and white wire pair).
CABLES SPECIFICATIONS (12VDC)
Cable section Maximum length
Low Power
illuminator
0.5mm²
10m (32ft)
(20AWG)
0.75mm²
16m (52ft)
(18AWG)
1mm²
22m (72.2ft)
(17AWG)
1.5mm²
32m (105ft)
(16AWG)
Tab. 1
CABLES SPECIFICATIONS (24VAC/VDC)
Cable section Maximum length
Low Power
illuminator
0.34mm²
25m (82ft)
(22AWG)
0.5mm²
40m (131ft)
(20AWG)
0.75mm²
60m (197ft)
(18AWG)
1.5mm²
120m (393ft)
(16AWG)
Tab. 2
For the telemetry cable (green and red colors), use a
conductor with a minimum cross-section of 0.34mm²
(22AWG) and a maximum length of 200m (656ft).
MNVCIRHS_1634_EN
High Power illuminator
6m (19.7ft)
9m (29.5ft)
12m (39ft)
18m (59.1ft)
High Power illuminator
15m (49.2ft)
22m (72.2ft)
35m (114ft)
70m (229ft)
7 Disposal of waste
materials
This symbol mark and recycle system
are applied only to EU countries and not
applied to the countries in the other area of
the world.
Your product is designed and manufactured with
high quality materials and components which can be
recycled and reused.
This symbol means that electrical and electronic
equipment, at their end-of-life, should be disposed of
separately from your household waste.
Please dispose of this equipment at your local
Community waste collection or Recycling centre.
In the European Union there are separate collection
systems for used electrical and electronic products.
8 Troubleshooting
8.1 Checking the power supply
Check that the unit is supplied with a voltage
between 12-24Vdc or 24Vac +/- 10%.
8.2 Check operation of the
twilight sensor
Check operation of the twilight sensor by darkening
it with black tape.
Leave the telemetry connection open.
9