Herunterladen Inhalt Inhalt Diese Seite drucken

Faults, Causes And Remedies; Spare Parts - Wilo CronoLine-IL Betriebsanleitung

Vorschau ausblenden Andere Handbücher für CronoLine-IL:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

English
10

Faults, causes and remedies

Fault
Pump does not start
or stops working
Pump is running at
reduced output
Pump is making noise
11

Spare parts

38
Only have faults remedied by qualified personnel! Observe the
safety instructions in chapter 9 "Maintenance" on page 34.
• If the malfunction cannot be rectified, consult a specialist techni-
cian or the nearest customer service or representative office.
Cause
Pump blocked
Cable terminal loose
Fuses faulty
Motor damaged
Motor protection switch has
triggered
Motor protection switch set
incorrectly
Motor protection switch
affected by excessive ambient
temperature
PTC thermistor tripping unit
has triggered
Incorrect direction of rotation
Stop valve on pressure side
throttled
Speed too slow
Air in the suction line
Insufficient supply pressure
Motor has bearing damage
Impeller grinding
Spare parts may be ordered via a local specialist retailer and/or Wilo-
customer service.
To avoid queries and incorrect orders, all data on the rating plate
should be submitted for each order.
CAUTION! Risk of damage!
Trouble-free pump operation can only be guaranteed when origi-
nal spare parts are used.
• Only use original Wilo spare parts.
• Each component is identified in the table below.
Information to be provided when ordering spare parts:
• Spare part number
• Name/description of the spare part
• All data on the pump and motor rating plate
NOTE
For all installation work, the forked spacer is required for setting the
correct impeller position in the pump housing.
Remedy
Disconnect motor from power supply, remove cause of
blockage; if motor blocked, overhaul/replace motor/plugs
Check all cable connections
Check fuses; replace defective fuses
Have the motor checked by Wilo customer service or a spe-
cialised service centre and serviced if necessary
Throttle the pump to the rated volume flow on the pressure
side
Set the motor protection switch to the correct nominal cur-
rent as shown on the rating plate.
Move the motor protection switch or protect it using heat
insulation
Check the motor and fan cover for contaminants and clean if
necessary, check ambient temperature and ensure an ambi-
ent temperature of Û 40°C by forced venting if necessary
Check direction of rotation, change if necessary
Slowly open the stop valve
Remedy incorrect terminal bridging (Y instead of )
Seal leaks at the flanges; bleed
Increase supply pressure, observe minimum pressure at the
suction port, check slide valve and filter on the suction side
and clean if necessary
Have the pump checked by Wilo customer service or a spe-
cialised service centre and serviced if necessary
Check faces and centrings and between lanterns and motor
and lantern and pump housing, clean if necessary.
Check the coupling and shaft sliding surfaces. If necessary,
clean and lightly oil them.
WILO SE 09/2010