ELECTRICAL CONNECTION
• Before connecting the appliance make sure that the voltage and frequency rated on the data plate conform
to those of the mains supply.
WARNING! A double pole trip switch with a least 3 mm between the contacts must be installed between the
unit and the mains supply.
• Connect the control and security device wires.
• Connect the power supply cable to the device.
• Do not use cables with aluminium conductors; do not solder the ends of cables which are to be inserted into
the binding posts; use cables which are marked T min 85°C and are resistant to atmospheric agents.
• The terminal wires must be positioned in such a way that both the wire and the insulating sheath are tightly
fastened (plastic binding is sufficient).
Terminal board connections
1-2
Programmer power supply 230 Vac
3-4-5
Motor command output Closing-Opening-Common
6-7
Power supply/motor earth binding posts
8-9
24 Vac 7 W output, powering external devices
10
TA (NO contact) opening button input
11
TC (NO contact) closing button input
12-13
CMN common for all inputs and outputs
14
TB (NC contact) blocking button input
15
CSP (NC contact) safety edge input. Opening this contact will provoke a travel direction inversion during
the closing stage and block movement during the opening stage (movement will continue the next time
a command is given).
16
FTC (NC contact) security device input ( inverting photocells during closing). The opening of this contact
will provoke a travel direction inversion during closure due to the cutting in of the safety device.
17
CSP_A analogical safety edge input (8.2 kΩ)
18
ANEM anemometer input (see anemometer functions on page 11)
19
Mass for radio receiver antenna
20
Radio receiver antenna pole
ALL UNUSED NC CONTACTS MUST BE BRIDGED
Power up the circuit and make sure that the indicator LEDs are in the following condition:
- L
Green power on LED
- L2
Red transmitter code management LED
- L3
Red time programming LED
If the green power on LED "L" does not light up check the condition of the fuses and the power cable contacts
at binding posts 1-2 (fig.1).
Setting the torque limiter
The torque can be set to minimum, seeing as the appliance will give a maximum power thrust each time it receives
a movement command
Position
"MIN"
equals:
Position
"A"
equals:
Position
"B"
equals:
Position
"C"
equals:
Position
"MAX"
equals:
To set the dip-switches; turn off the power to the programmer, change the settings and then switch the
power back on.
Jumper "REMOTE MEMO"
Inserted:
memorization via radio enabled
Deactivated:
memorization via radio disabled
Jumper "SEL_FTC"
Inserted:
the photocells will impede the activation of the motor if an alarm condition is present
Deactivated:
the photocells function as a safety device only while the shutter is closing
Jumper "CSP_A ENABLE"
Inserted:
analogical safety edge enabled
Deactivated:
analogical safety edge disabled
20 Vac
45 Vac
70 Vac
95 Vac
230 Vac
0
ON
OFF
OFF