Herunterladen Inhalt Inhalt Diese Seite drucken

Functioning Anomalies - Bosch TCE 5330 Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
5.6

Functioning anomalies

In the following table all the possible anomalies and their correspondent remedies are listed.
Other supposable functioning anomalies are mainly of technical nature and have to be verified and resolved by
qualified technicians.
In any case contact the assistance service of the authorized vendor of Bosch equipment.
i
To speed up intervention it is important to tell during the phone call the data reported on the identification
plate (tag on the back of the TCE 5330) and the type of malfunction.
!
Any intervention on the electrical, hydraulic or pneumatic system, has to be performed exclusively by qualified
technicians which are properly trained.
Anomalies
The locking plate does not turn in any of the two directions. 1. The network plug is
When the locking flange pedal is pressedthe lo-
cking plate turns in the direction opposite of that
shown by the arrow on the control unit motor.
The locking plate transmits insufficienttorque (low force).
The locking plate does not lock the rim correctly.
The TCE 5330 makes no hydraulic motion.
Robert Bosch GmbH
Operating instructions | TCE 5330 | 39
Causes
not connected.
2. The network plug is not
correctlyconnected.
3. The tension does not corres-
pond tothe prescribed value.
4. The main switch hasn't
been turned on.
5. Burnt fuses.
1. Phases inversion du-
ringplug connection.
1. Wrong network tension.
2. Loosen transmissionbelt.
3. Burnt fuses.
1. Phases inversion du-
ringplug connection.
2. The pressure reducing valve is
closed or incorrectly adjusted.
1. The control unit motor turns
in the wrong direction.
2. The thermal magnetic cir-
cuit breakeris turned off.
3. A fuse has blown up.
Remedies
1. - 2. Check that the network
plug is correctly inserted in the
socket and check connection.
3. Check the power supplytension.
4. Turn on the main switch.
5. Replace the fuses.
1. Invert the 2 phases in
the network plug (qualifie-
delectrician is required).
1. Check the correspon-
dence of the network tensi-
on and the tension shown
on theidentification plate.
2. Pull the transmission belt.
3. Replace the fuses.
1. Invert the 2 phases in
the network plug (qualifie-
delectrician is required).
2. Open or adjust correctly-
the pressure reducingvalve.
1. Invert the phases in
the tensionplug.
2. Turn on the thermal-ma-
gnetic circuit breaker.
3. Replace the fuse.
|
1 695 301 841
2010-02-16
en

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis