7.8.3 Instance 1, Attributes

Attr.-ID
Access
Name
0x01
Get
Status
Configuration
0x02
Get
Capability
Configuration
0x03
Set/Get
Control
Physical Link
Object
Path size
0x04
Get
Path
Interface
Configuration
IP Address
Network Mask
0x05
Set/Get
Gateway
Address
Name Server
Name Server
Domain Name
0x06
Get
Host Name
Table 25: TCP/IP Interface, Overview of the instance attributes
Printed in the Federal Republic of Germany
09/11/2017
Data type
Description
DWORD
Interface status
Interface capability
flags, indicate the
DWORD
configuration
options.
Interface control
flags, the bits adjust
DWORD
the configuration
possibilities.
STRUCT
Path to physical link
of:
object
Size of path,
UINT
number of 16 bit
words in path.
Logical segments
Padded
identifying the
EPATH
physical link object.
TCP/IP network
STRUCT
interface
of:
configuration.
The device's IP
UDINT
address.
The device's
UDINT
network mask.
Default gateway
UDINT
address.
UDINT
not implemented
UDINT
not implemented
STRING
not implemented
The device's host
STRING
name.
TR - ELE - BA - DGB - 0020 - 08
Default
Page
0x00 00 00 02
Device obtains IP
parameter from
148
DHCP, if hard-
ware switches =
0x00 or 0xFF
0x00 00 0014
Device corre-
sponds to a
148
DHCP client, con-
figuration can be
changed.
0x00 00 00 02
Device obtains IP
parameter from
148
DHCP, if hard-
ware switches =
0x00 or 0xFF
149
0x00 02
149
The path is
restricted to one
logical class
segment and one
149
logical instance
segment:
0x20 0xF6,
0x24 0x01
149
FLASH contents
149
FLASH contents
149
FLASH contents
149
0x00 00 00 00
0x00 00 00 00
0
"LE200_ENIP"
 TR-Electronic GmbH 2010, All Rights Reserved