For Users and Technicians
button
. As the device is heating up the LED
going out again as soon as the set temperature is reached. The "fast-
heating" switches itself off automatically.
Boiler mode operation
In this mode the hot water storage unit heats the contents of the
reservoir once upon the initial operation at the connected and
configured basic performance. Each further heating procedure must be
started manually by pressing the button fast-heating
6.6
LED display anode and service
In normal operations, the LED "anode"
"service"
is off.
If one of the two LEDs flashes, this indicates an "error condition".
To begin with, please reset the device
follows:
to the setting " ● ".
Firstly turn the dial
After that, press the "fast-heating" button
If the cause of the error condition does not exist directly after the reset,
the device will again return to its normal mode of function. Otherwise the
device will again indicate an "error condition".
In this case please contact the customer service operator.
6.7
Cleaning
• Wipe with a damp cloth. Do not use any sharp or coarse cleaning
products.
• Do not use a steam cleaner.
6.8
Customer Service
In order to avoid hazards, repairs may only be carried out by a
customer service operator licensed by us.
The initial service through our customer service operator should take
place around two years after the first operation. At this time, the device
will potentially be decalcified. Afterwards, the customer service
operator will recommended a date for the next service. Specify the E-No.
and FD-No. when phoning the customer service operator!
When requesting customer service, please enter the E-No. and the FD-
No. of your device.
You will find the numbers on identification plate between the water
access pipes of the reservoir.
6.9
Disposal
This appliance is labelled in accordance with European Directive 2012/
19/EU concerning used electrical and electronic appliances (waste
electrical and electronic equipment - WEEE). The guideline determines
the framework for the return and recycling of used appliances as
applicable throughout the EU.
Please ask your specialist retaller about current disposal facilities.
Subject to change.
20
lights up, before
.
is constantly lit, the LED
RESET. To do this, proceed as
.
TR5500T – 6 720 875 993 (2017/12)