Simple troubleshooting
Problem
The water filter does not
stay in position in the water
tank 11.
The coffee grounds are not
compact and are too wet.
Display shows
P
LEASE CHECK BREWING
UNIT
Coffee or milk froth quality
varies considerably.
Water dripped onto the inner
floor of the appliance when
the drip tray was removed.
If you are unable to solve the problem, please call the hotline.
Cause
The water filter is not
correctly engaged.
The grind setting is too fine
or too coarse, or you are
not using enough pre-
ground coffee.
Brewing unit is soiled.
Too much pre-ground
coffee in the brewing unit.
Build-up of limescale in the
appliance.
Drip tray removed too early. Wait a few seconds after
Solution
Press the water filter firmly
into the tank attachment
until you feel it engage.
Adjust the grinding unit to a
coarser or finer setting, or
use 2 level measuring
spoons of ground coffee.
Clean brewing unit.
Clean brewing unit.
(Pour in no more than 2
level measuring spoons of
ground coffee).
Descale the appliance with
two descaling tablets as
described in the instructions.
the last drink was dispensed
before removing the drip
tray.