Parker EME
Detailliert:
Compax3 1AC
Power supply
X1/1
X1
L
X1/2
N
X1/3
PE
Compax3 3AC
Power supply
X1/1
X1
L1
X1/2
L2
X1/3
L3
X1/4
PE
Ballast resistor (1AC)
X2
X2/1
res.
X2/2
-R
X2/3
PE
X2/4
+R
X2/5
res.
Ballast resistor (3AC)
X2
X2/1
+R
X2/2
-R
X2/3
PE
X2/4
+HV
X2/5
-HV
Motor/Brake
X3
X3/1
U
X3/2
V
X3/3
W
X3/4
PE
X3/5
Br+
X3/6
Br-
24VDC Control voltage/
Enable
X4
X4/1
+24V Input
X4/2
GND24V
X4/3
Enable_in
X4/4
Enable_out_a
X4/5
Enable_out_b
Die Bestückung der einzelnen Stecker ist abhängig von der
Compax3-Ausbaustufe. Teilweise ist die Belegung von der bestückten Compax3 -
Option abhängig.
X10/1
RS485 +5V
RS485 +5V
X10/2
RxD
X10/3
TxD/
TxD_RxD/
X10/4
res.
X10/5
GND
X10/6
res.
X10/7
TxD
TxD_RxD/
X10/8
RxD/
X10/9
+5V
X22/1
+24Vout
+24Vout
X22 /2
Uin3+
X22 /3
GND
X22 /4
Uin3-
X22 /5
+24Vout
+24Vout
X22 /6
Uin4+
X22 /7
GND
X22 /8
Uin4-
X22 /9
+24V0ut
+24V0ut
X22 /10
Uin5+
X22 /11
GND
X22 /12
Uin5-
+24Vin
GND in
Input24VDC
O10/I10
O11/I11
InputGND
X13/1
Sense-
X13/2
Sense+
X13/3
Hall1
X13/4
Vcc(+5V)
Vcc(+8V)
X13/5
+5V
X13/6
CLKfbk
Hall2
X13/7
Sin-/A-
X13/8
Sin+/A+
X13/9
Hall3
CLKfbk/
X13/10
Tmot
X13/11
COS-/B-
COS-
X13/12
COS+/B+
COS+
X13/13
N+
DATAfbk
X13/14
DATAfbk/
N-
X13/15
GND(Vcc)
GND(Vcc)
Die eingezeichnete Brücke an X4 (links in rot) dient zur Freigabe des Geräts für
Testzwecke. Im Betrieb wird der Enable - Eingang meist von extern geschaltet.
190-120104N15 C3IxxT30 Juni 2014
X10/1
EnableRS232 0V
X10/2
res.
X10/3
X10/4
res.
X10/5
GND
X10/6
res.
X10/7
X10/8
res.
X10/9
+5V
X22/1
Output +24V
X22 /2
Iin0+
X22 /3
GND
D/A-channel1
X22 /4
Iin0-
D/A-channel0
X22 /5
X22 /6
Iin1+
X22 /7
GND
X22 /8
Iin1-
X22 /9
Ain0+
X22 /10
Iin2+
Ain1+
X22 /11
GND
X22 /12
Iin2-
X22 /13
X22 /14
X22 /15&16
Shield
X22/1
res.
Output+24V
X22 /2
O0/I0
Output 0
X22 /3
O1/I1
Output 1
X22 /4
O2/I2
Output 2
X22 /5
O3/I3
Output 3
X22 /6
Input 0
O4/I4
X22 /7
O5/I5
Input 1
X22 /8
O6/I6
Input 2
X22 /9
O7/I7
Input 3
X22 /10
Input 4
O8/I8
X22 /11
Input+24V
X22 /12
O9/I9
Input 5
X22 /13
Input 6
X22 /14
Input 7 or (MN-INI)
X22 /15
GND24V
X13/1
res.
X13/2
res.
X13/3
GND
X13/4
REF+Resolver
X13/5
+5V
X13/6
CLKfbk
X13/7
SIN-
X13/8
SIN+
X13/9
CLKfbk/
X13/10
Tmot
X13/11
COS-
X13/12
COS+
X13/13
X13/14
X13/15
REF-Resolver
Compax3S Anschlüsse
Stecker- und Pinbelegung C3S
X10/1
Rx
X10/2
Rx/
RxD
X10/3
Lx
TxD
X10/4
res.
DTR
X10/5
res.
GND
X10/6
Lx/
DSR
X10/7
res.
RTS
res.
X10/8
CTS
X10/9
+5V
Tx
Tx/
X11/1
Lx
X11/2
Ain1-
res.
X11/3
res.
X11/4
Lx/
X11/5
+5V
res.
X11/6
A/
res.
X11/7
A
X11/8
Tx+
B
X11/9
Tx-
X11/10
Rx+
X11/11
res.
Ain0-
X11/12
res.
B/
X11/13
Rx-
N/
X11/14
res.
N
X11/15
res.
GND
Tx+
X12/1
Tx-
X12/2
Rx+
X12/3
res.
X12/4
res.
X12/5
Rx-
X12/6
res.
X12/7
res.
X12/8
X12/9
res.
X12/10
res.
X12/11
Data line-B
X12/12
RTS
X12/13
GND
X12/14
+5V
X12/15
res.
Data line-A
res.
X13/1
res.
X13/2
res.
res.
X13/3
GND
CAN_L
X13/4
GNDfb
X13/5
+5V
res.
X13/6
SHIELD
X13/7
res.
SIN-
X13/8
CAN_H
SIN+
X13/9
res.
X13/10
res.
Tmot
X13/11
-VDC
X13/12
CAN_L
X13/13
res.
Shield
X13/14
res.
CAN_H
X13/15
+VDC
X20/1
X20/2
X20/3
X20/4
X20/5
X20/6
X20/7
X20/8
X21/1
X21/2
X21/3
X21/4
X21/5
X21/6
X21/7
X21/8
X23/1
X23/2
X23/3
X23/4
X23/5
X23/6
X23/7
X23/8
X24/1
X24/2
X24/3
X24/4
X24/5
X24/6
X24/7
X24/8
X23/1
X23/2
X23/3
X23/4
X23/5
X23/6
X23/7
X23/8
X23/9
X23/1
X23/2
X23/3
X23/4
X23/5
X23/6
X23/7
X23/8
X23/9
X23/1
X23/2
X23/3
X23/4
X23/5
35