Herunterladen Inhalt Inhalt Diese Seite drucken

Battery Removal/Installation - Hitachi DV 14DL Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für DV 14DL:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 15
English

BATTERY REMOVAL/INSTALLATION

1. Battery removal
Hold the handle tightly and push the battery latch (2
pcs.) to remove the battery (see Figs. 1 and 2).
CAUTION
Never short-circuit the battery.
2. Battery installation
Insert the battery while observing its polarities (see
Fig. 2).
CHARGING
Before using the impact driver drill, charge the battery as
follows.
1. Connect the charger's power cord to a receptacle
When the power cord is connected, the charger's
pilot lamp will blink in red (At 1-second intervals).
2. Insert the battery into the charger
Table 1
Before
charging
While
charging
Charge status
lamp (RED)
Charging
complete
Charging
impossible
Overheat lamp
Overheat
(GREEN)
standby
NOTE: When standby for cooling battery, UC18YRL cools the overheated battery by cooling fan.
(2) Regarding the temperatures of the rechargeable
battery
The temperatures for rechargeable batteries are as
shown in Table 2, and batteries that have become
hot should be cooled for a while before being
recharged.
Table 2 Recharging ranges of batteries
Rechargeable batteries
BCL1430, EBL1430
EBM1430, EBM1830
(3) Regarding recharging time
Depending on the combination of the charger and
batteries, the charging time will become as shown
in Table 3.
9
Indications of the pilot lamp
Lights for 0.5 seconds. Does not light for 0.5
Blinks
seconds. (off for 0.5 seconds)
(RED)
Lights continuously
Lights
(RED)
Lights for 0.5 seconds. Does not light for 0.5
Blinks
seconds. (off for 0.5 seconds)
(RED)
Lights for 0.1 seconds. Does not light for 0.1
Flickers
seconds. (off for 0.1 seconds)
(RED)
Lights
Lights continuously
(GREEN)
Temperatures at
which the battery
can be recharged
0°C – 50°C
Firmly insert the battery into the charger till it contacts
the bottom of the charger and checking the polarities
as shown in Fig. 3.
CAUTION
If the batteries are inserted in the reverse direction,
not only recharging will become impossible, but it
may also cause problems in the charger such as a
deformed recharging terminal.
3. Charging
When inserting a battery in the charger, charging will
commence and the pilot lamp will light continuously
in red.
When the battery becomes fully recharged, the pilot
lamp will blink in red (At 1-second intervals) (See
Table 1).
(1) Pilot lamp indication
The indications of the pilot lamp will be as shown in
Table 1, according to the condition of the charger or
the rechargeable battery.
Table 3 Charging time (At 20°C)
Charger
Battery
BCL1430, EBL1430
EBM1430, EBM1830
NOTE
The charging time may vary according to temperature
and power source voltage.
4. Disconnect the charger's power cord from the
receptacle
5. Hold the charger firmly and pull out the battery
NOTE
After charging, pull out batteries from the charger
first, and then keep the batteries properly.
Regarding electric discharge in case of new
batteries, etc.
As the internal chemical substance of new batteries
and batteries that have not been used for an extended
Malfunction in the battery
or the charger.
Battery overheated.
Unable to charge.
(Charging will commence
when battery cools)
UC18YRL
Approx. 45 min.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Dv 18dl

Inhaltsverzeichnis