Herunterladen Inhalt Inhalt Diese Seite drucken

Screen Structure Of Control Menus; Parameter: Trim; Parameter: Step (Trim Increment); Parameter: Idle (Idle Trim) - Multiplex ROYALevo 7 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für ROYALevo 7:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
ROYAL evo 7
14.1.

Screen structure of control menus

Our example shows the screen display for the aileron
control, with all the available set-up parameters. The
display may not look exactly like this as it depends upon
the transmitter control and its available parameters.
The screen is divided into three sections:
1.
Name of control and active flight phase
At the top is the name of the transmitter control (in
our example Aileron). Next to it is the name of
the active flight phase (in our example the NORMAL
flight phase).
2.
Parameter list
On the left you see all the parameters of the trans-
mitter control you have selected together with the
set values, all clearly laid out.
3.
Graph
The graph on the right displays the effect of all the
settings in graphic form. The curve of the graph
immediately reflects changes in the settings and
makes the behaviour of the control easier to un-
derstand. The dotted vertical line shows the cur-
rent position of the transmitter control.
Next to the parameters you will see two additional indi-
cators:
The small, high-set dash following the parameter name
indicates that this value can be assigned to one of the
3D digi-adjustors, and can then be adjusted in flight (
11.2.2.).
Expo —
The small number after the parameter name (1 to 4) in-
dicates that this parameter can be set to a different
value for each flight phase (
Trim ˜
Some parameters can be assigned to the 3D digi-
adjustor and also be changed separately for each flight
phase. In this case both symbols are displayed.
Trvl –

Parameter: Trim

14.2.
for controls:
Aileron, elevator, rudder
Roll, pitch-axis, yaw
for controls:
Display only
One trim value for each flight phase
The positional display of the digital trim takes the form
of a bar graph in status displays 1 and 2 (
Trim parameter also shows the trim setting of the
transmitter control in each flight phase as a % value.
-90%
18.4).
2.0%
-90%
10.7.). The

Parameter: Step (trim increment)

14.3.
for controls:
Aileron, elevator, rudder, throttle
Roll, pitch-axis, yaw
for controls:
Adjust. range
1.5% (= normal) / 0.5% (= fine)
The digital trims of the ROYALevo7 have a trim range of
±20 increments. With Step you can determine the trim
change in % trim increment. The maximum trim range is
±10% when Step is 0.5%, and ±30% when Step is
1.5%.
!
Note
If you change the increment size and one transmit-
ter control trim is already off-centre, the actual trim
setting will change. In this case you must adjust
the trim setting to obtain the original deflection.
In most cases a trim increment of 1.5% proves to be
ideal. However, for very fast models with precision con-
trol linkages, and models with very large control surface
travels (e.g. fun-fly models) the 1.5% trim increment
may be excessive. In this case you should set Step to
0.5%, as this provides ultra-fine trim control.

Parameter: Idle (idle trim)

14.4.
For control:
Throttle
Display only
Idle trim is necessary for models powered by internal
combustion motors. The motor is required to run at a
safe idle when the throttle stick (throttle control) is at
the idle end-point. The throttle trim can be adjusted at
any time to set and adjust the idle speed. The trim for
the throttle control therefore only affects the bottom
half of the travel, i.e. from idle to half-throttle.
The neutral (idle) position of the throttle control is se-
lected at the Thr. min parameter in the Setup /
Control menu (
Like Trim, the Idlel parameter only provides informa-
tion, and shows the idle setting in %. The idle setting is
displayed in graphic form in status displays 1 and 2.
Page 32
13.3.3.).

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis