XA00518F-E
22
Device type
FMP50, FMP51, FMP52, FMP53, FMP54, FMP55, FMP56, FMP57
Basic specifications
Position 1, 2 (Approval)
Selected option
1)
FMP5x
BG
2)
BH
3)
IG
4)
IH
1)
The designation changes in connection with Position 4 (Display, Operation) = L, M or N:
II 3 G Ex nA [ia Ga] IIC T6 Gc
2)
The designation changes in connection with Position 4 (Display, Operation) = L, M or N:
II 3 G Ex ic [ia Ga] IIC T6 Gc
3)
The designation changes in connection with Position 4 (Display, Operation) = L, M or N:
Ex nA [ia Ga] IIC T6 Gc
4)
The designation changes in connection with Position 4 (Display, Operation) = L, M or N:
Ex ic [ia Ga] IIC T6 Gc
Position 3 (Power Supply, Output)
Selected option
FMP5x
E
G
Position 4 (Display, Operation)
Selected option
FMP5x
A
C
E
1) 2)
L
1) 2)
M
1) 3)
N
1)
FHX50 is approved according to DEK12.0046X or DEKRA 12ATEX0151X.
2)
In connection with Position 5 (Housing) = A: Observe the specifications in the "Overvoltage protection" and
"Temperature tables" chapters!
3)
Only in connection with Position 5 (Housing) = B or C
Position 5 (Housing)
Selected option
1)
FMP5x
A
C
FMP51
B
FMP52
FMP54-57
1)
Only in connection with Position 1, 2 (Approval) = BH or IH
Levelflex FMP50/51/52/53/54/55/56/57
Description
ATEX II 3 G Ex nA IIC T6 Gc
ATEX II 3 G Ex ic IIC T6 Gc
IECEx Ex nA IIC T6 Gc
IECEx Ex ic IIC T6 Gc
Description
2-wire, FOUNDATION Fieldbus, switch output (PFS)
2-wire, PROFIBUS PA, switch output (PFS)
Description
Without, via communication
SD02, 4-line, push buttons + data backup function
SD03, 4-line, illum., touch control + data backup function
Prepared for display FHX50 + M12 connection
Prepared for display FHX50 + custom connection
Prepared for display FHX50 + NPT1/2"
Description
GT19 dual compartment, plastics PBT
GT20 dual compartment, Alu coated
GT18 dual compartment, 316L
Endress+Hauser