22 | English
The vibration level given in these instructions has been
measured in accordance with a standardised measuring pro-
cedure and may be used to compare power tools. It can also
be used for a preliminary estimation of exposure to vibra-
tion.
The stated vibration level applies to the main applications of
the power tool. However, if the power tool is used for differ-
ent applications, with different application tools or poorly
maintained, the vibration level may differ. This can signific-
antly increase the exposure to vibration over the total work-
ing period.
To estimate the exposure to vibration accurately, the times
when the tool is switched off or when it is running but not ac-
tually being used should also be taken into account. This can
significantly reduce the exposure to vibration over the total
working period.
Implement additional safety measures to protect the oper-
ator from the effects of vibration, such as servicing the
power tool and application tools, keeping the hands warm,
and organising workflows correctly.
Fitting
Fitting protective equipment
Pull the plug out of the socket before carrying out any
u
work on the power tool.
Note: If the grinding disc breaks during operation or the
holding fixtures on the protective guard/power tool become
damaged, the power tool must be sent to the after-sales ser-
vice immediately; see the "After-sales service and advice on
using products" section for addresses.
Protective guard for grinding
clicks into place.
Adjust the position of the protective guard (7) to meet the
requirements of the operation. To do this, push the unlock-
ing lever (1) upward and rotate the protective guard (7) into
the required position.
Always position the protective guard (7) such that all
u
three red cams on the unlocking lever (1) engage in
the corresponding openings on the protective guard
(7).
1 609 92A 4FB | (15.01.2019)
Place the protective guard
(7) onto the holder on the
power tool until the coding
cams of the protective
guard are aligned with the
holder. When doing so,
press and hold the unlock-
ing lever (1).
Press the protective guard
(7) onto the spindle collar
until the shoulder of the
protective guard is sitting
on the flange of the power
tool and rotate the protect-
ive guard until it audibly
Adjust the protective guard (7) such that sparking in
u
the direction of the operator is prevented.
The protective guard (7) must only be adjustable
u
while the unlocking lever (1) is actuated. Otherwise,
the power tool must not be used any more under any
circumstances and must be sent to the after-sales ser-
vice.
Note: The coding cams on the protective guard (7) ensure
that only a protective guard that is suitable for the power
tool can be fitted.
Protective guard for cutting
Always use the protective guard for cutting (9) when
u
cutting bonded abrasives.
Provide sufficient dust extraction when cutting stone.
u
The protective guard for cutting (9) is fitted in the same way
as the protective guard for grinding (7).
Extraction guard for cutting with a guide block
The extraction guard for cutting with a guide block (18) is fit-
ted in the same way as the protective guard for grinding (7).
Side handle
Do not operate your power tool without the side
u
handle (6).
Screw the side handle (6) on the left or right of the machine
head depending on how your are working.
Low-vibration auxiliary handle
ably.
Do not make any alterations of any kind to the auxili-
u
ary handle.
Do not continue to use a damaged auxiliary handle.
Hand guard
Always fit the hand guard (14) when working with the
u
cup brush/disc brush (15) or diamond core cutter (20).
Attach the hand guard (14) to the auxiliary handle (6).
Fitting and removing abrasive tools
Pull the plug out of the socket before carrying out any
u
work on the power tool.
Do not touch grinding and cutting discs until they have
u
cooled down. The discs can become very hot while work-
ing.
Only use original X-LOCK application tools that carry the
u
X-LOCK logo. A maintained clamping gauge of max.
1.6 mm can only be guaranteed with original X-LOCK ap-
plication tools. A higher clamping gauge can lead to insec-
ure clamping, potentially causing the clamp tool to come
loose.
X-LOCK application tools do not need additional clamping
u
flanges or support flanges.
The low-vibration auxiliary
handle reduces vibration,
enabling the tool to be used
safely and more comfort-
Bosch Power Tools