7.
Maintenance
!
Work on electrical equipment is only to be
performed by persons with sufficient knowledge
and experience of electrical systems!
7.1
Cleaning
!
Do not use abrasive cleaning agents and coarse
workshop cloths!
The housing and the LCD are only to be cleaned
using a soft cloth and neutral cleaning agents.
7.2
Spare and wearing parts
Designation
Power supply cable 3 m
<)
Red/black charging cable set (3 m; 6 mm
Red/black charging cable set (5 m; 6 mm
Wall mounting
Wearing part
<)
8.
Decommissioning
8.1

Temporary shutdown

In the event of lengthy periods of non-use:
Disconnect BAT 645 from the mains voltage system.
8.2
Change of location
If the BAT 645 is passed on, all the documentation
included in the scope of delivery must be handed
over together with the unit.
The BAT 645 is only ever to be transported in the
original or equivalent packaging.
Unplug the electrical connection.
Heed the notes on initial commissioning.
8.3
Disposal and scrapping
1. Disconnect the BAT 645 from the mains and detach
the power cord.
2. Dismantle the BAT 645 and sort out and dispose
of the different materials in accordance with the
applicable regulations.
Robert Bosch GmbH
Only for EC countries:
Order number
1 684 461 195
)
1 687 011 534
2
<)
)
1 687 011 536
2
<)
9.
1 688 005 253
Property
Maximum charging current
Length of charging cable
Charging cable cross-section
Max. power consumption
Weight (without accessories)
Charging characteristic of
universal battery
Charging cut-off voltage U2 for
universal battery (temperature-
regulated)
12 V
24 V
Back-up mode 12 V
Back-up mode 24 V
Buffer mode 12 V
Buffer mode 24 V
Function temperature range
Storage temperature range
Transport temperature range
Mains voltage
Mains frequency (230 V)
Rated battery voltage
Protection class (EN 60529:1991 +
A1:2000 + A2:2013)
Protection class
(EN 61140:2002 + A1:2006)
Dimensions (W x H x D)
Dimensions (W x H x D) (USA)
Workplace-related
noise emission value (Lpa)
Maintenance | BAT 645 | 23 |
BAT 645, accessories and packaging should be
sorted for environmental-friendly recycling.
Do not dispose BAT 645 into household
waste.
The BAT 645 is subject to the European
directive 2012/19/EC (WEEE).
Dispose of used electrical and electronic
devices, including cables, accessories and
batteries, separately from household waste.
Make use of the local return and collection
systems for disposal.
Proper disposal of BAT 645 prevents
environmental pollution and possible
health hazards.

Technical Data

Value, range
45 A
3 m / 9.8 ft
6 mm
800 W
3.7 kg / 8.2 lb
I1U1I2aI3aI3...
14,2 V – 14,8 V
28,4 V – 29,6 V
11 V – 14.2 V / 3 A – 20 A
22 V – 28.4 V / 3 A – 20 A
11 V – 14.2 V / 3 A – 45 A
22 V – 28.4 V / 3 A – 22 A
-5 °C – 45 °C
-25 °C – 60 °C
230 VAC +6%/-10%
50 Hz / 60 Hz ±4%
12 V / 24 V
IP 20D
I
220 x 116 x 296 mm
8.7 x 4.6 x 11.6 inch
< 60 dB(A)
(with fan on)